| Date |
Text |
| 2016-09-12 16:33:00 | BUILDING PLAN REVIEW |
| | W. P. B. PERMIT: 16081061 |
| | ADD: 2471 OKEECHOBEE BLVD. SUITE PS |
| | CONT: TO BE DETERMINED |
| | TEL: 561-373-3902 |
| | E-MAIL: [email protected] |
| | |
| | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| | ADMINISTRATION |
| | |
| | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. |
| | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND |
| | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE |
| | FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 1ST REVIEW |
| | DATE: MON. SEPT. 12/ 2016 |
| | ACTION: BUILDING PROVISO |
| | |
| | 1) BEFORE THE START OF WORK A REVISION WOULD BE |
| | REQUIRED SHOWING HOW PROTECT OF THE PEDESTRIANS |
| | ENTERING AND EXITING THE STORE. SHOW COMPLIANCE WITH |
| | 2014 FBC-B |
| | 3306.7 COVERED WALKWAYS. COVERED WALKWAYS SHALL HAVE A |
| | CLEAR HEIGHT OF NOT LESS THAN 8 FEET (2438 MM) AS |
| | MEASURED FROM THE FLOOR SURFACE TO THE CANOPY OVERHEAD. |
| | ADEQUATE LIGHTING SHALL BE PROVIDED AT ALL TIMES. |
| | COVERED WALKWAYS SHALL BE DESIGNED TO SUPPORT ALL |
| | IMPOSED LOADS. IN NO CASE SHALL THE DESIGN LIVE LOAD BE |
| | LESS THAN 150 PSF (7.2 KN/M2) FOR THE ENTIRE STRUCTURE. |
| | |
| | 2) THE BACKSIDE OF THE PARAPET SHOWS THE INSTALLATION |
| | OF ASPHALT ROOF SHINGLES. PLEASE PROVIDE COMPLIANCE |
| | WITH 1609.6.4.4.1 COMPONENTS & CLADDING. |
| | FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV. |
| | 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION |
| | SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS: |
| | (31)(D) ROOFING PRODUCTS AND ASSEMBLIES. |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | CONSTRUCTION SERVICES DIVISION |
| | DEVELOPMENT SERVICES DEPARTMENT |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |