2016-08-25 15:02:27BUILDING PLAN REVIEW
 W. P. B. PERMIT: 16080983 INSTALLATION OF 100 FT. TALL
 PERIMTER FOUL BALL POLES & NETTING
 ADD: 5001 N. MILITARY TRL.
 CONT: CONSTRUCTION SOLUTIONS OF THE PALM BEACHES, LLC
 TEL: 904-534-4564
 E-MAIL: [email protected]
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE.
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: THURS. AUGUST 25/ 2016
 ACTION: DENIED
  
 1) SOILS REPORT BALL PARK OF THE PALM BEACHES FILE NO.
 15-1636 PAGE 15 INDICATES 3 SPT BORINGS (MAB-1TO MAB-3)
 WERE MADE FOR THE MAST ARMS, BUT NO TEST WERE PERFORMED
 FOR THE 100 FOOT TALL POLES AND NETTING THAT SURROUND A
 PORTION OF THE SITE THESE VALUES ARE UNKNOWN VALUES.
 THE SOILS ENGINEER HAS NOT BEEN PROVIDED WITH ANY
 SPECIFIC INFORMATION OF LOADING AND OR CONFIGURATION OF
 THE POLES AND OR FOUNDATIONS.
 FBC-B 1803.5.2 QUESTIONABLE SOIL. WHERE THE
 CLASSIFICATION, STRENGTH OR COMPRESSIBILITY OF THE SOIL
 IS IN DOUBT OR WHERE A LOAD-BEARING VALUE SUPERIOR TO
 THAT SPECIFIED IN THIS CODE IS CLAIMED, THE BUILDING
 OFFICIAL SHALL BE PERMITTED TO REQUIRE THAT A
 GEOTECHNICAL INVESTIGATION BE CONDUCTED.
  
 2) SHEET S1 INDICATES THE APPROXIMATE LOCATIONS TYPICAL
 100 FT. TALL NETTING POLES AT A MAXIMUM SPACING OF 50
 FEET. COORDINATE WITH CIVIL AND ARCHITECTURAL FOR THE
 EXACT POLE LOCATIONS. IT SOUNDS LIKE THIS PLAN IS A
 PRELIMINARY PLAN AND NOT ONE TO BE BUILT BY, EXACT
 LOCATIONS NOT PROVIDED. 107.2.1.3 ADDITIONAL
 INFORMATION IS REQUIRED. 107.2.1.3.
  
 3) SHEET S5.2 PROVIDES THE WIND DESIGN FOR THE POLES
 AND NETTING. THERE ARE (2) BUILDING RISK CATEGORIES
 PROVIDED I & II WITH THE ASSOCIATED WIND SPEED OF 150 &
 170 VULT MPH PLEASE PROVIDE WHY THE 2 VARYING WIND
 DESIGNS AND WHERE ARE THE 2 LOCATIONS DESIGNATED ON THE
 PLANS. ALL BUILDINGS AND STRUCTURES THAT ARE PART OF
 THE STADIUM ARE DESIGNED TO A BUILDING RISK CATEGORY
 III AND 180 MPH VULT. THE OUT BUILDINGS ARE BEING BUILT
 AT 170 MPH VULT RISK CATEGORY II. FBC-B 1603.1.4(2) .
  
 4) STRUCTURAL CALCULATIONS PREPARED BY P. E. JOHN
 CANNON JONES PAGE 5/10 IS A WIND LOADING ANALYSIS FOR
 STACKS, CHIMNEYS AND VERTICAL TANKS AND REFERENCES AN
 ASCE 7-02 PROGRAM. WE ARE UNDER THE 2014 FBC-B & ASCE
 7-10 SHOULDN?T THE PROGRAM BE UPDATED. THE SHEET 5 OF
 10 ( JOB NUMBER 100) DOES REFERENCE THE POLE HEIGHT OF
 100 FEET AND WIDTH BETWEEN POLES 50 FEET. THERE ARE 2
 MORE CHARTS ONE LABELED JOB NUMBER 20 THE OTHER JOB
 NUMBER 30 THE D DIMENSION ON THESE CHARTS IS 0.50 AND
 0.67 FEET? PLEASE PROVIDE ADDITIONAL INFORMATION
 107.2.1.3.
  
 5) SHEET 7 OF 10 POLE FOOTING EMBEDDED IN SOIL
 INDICATES THE POLE BEING 56 FEET 7 3/8 ABOVE GRADE AND
 21 FOOT 3 INCHES BELOW GRADE WHERE AS SHEET NCPN-1.1
 SHOWS THE POLES 100 FOOT TALL?
  
 6) SHEET S3 FOUL POLE DETAILS DID NOT LOAD PROPERLY???
 NEED MORE INFORMATION 107.2.1.3.
 7) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION
 DEVELOPMENT SERVICES DEPARTMENT
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  