| 2017-07-27 14:58:04 | 07/27/17 MET WITH ALVIN. NEED TO REVISE ENERGY |
| | CALCULATIONS. NEED CORRECT CALCULATIONS, NOT WORST |
| | CASE. HE SIGNED OUT ONE COMPLETE SET OF PLANS AND |
| | PRODUCT APPROVALS. JG. |
| | |
| | |
| | RESIDENTIAL (R3) CHANGE OF USE/ALTERATION THIRD |
| | BUILDING REVIEW CHECKLIST. |
| | CODE: FBC 5TH EDITION (2014). |
| | |
| | 1- MISSING PLANS WITH THE PALM BEACH COUNTY STAMP FOR |
| | IMPACT FEES. PLEASE BRING COPY OF PLANS THAT WERE |
| | STAMPED BY PALM BEACH COUNTY. COUNTY IMPACT FEE |
| | ORDINANCE OF THE UNIFIED LAND DEVELOPMENT CODE. |
| | |
| | 2- REVISE ENERGY CALCULATIONS SUBMITTED FOR THE GARAGE |
| | CONVERSION: |
| | A) OWNER NEEDS TO CERTIFY AT BOTTOM OF FORM AS REQUIRED |
| | BY SEC. R103.1.1.2 FBC-ENERGY CONSERVATION, 5TH EDITION |
| | (2014). PERMIT CAN NOT BE ISSUED WITHOUT THE ENERGY |
| | CALCULATIONS. |
| | |
| | B) ITEM #5 INDICATES THAT CALCULATIONS ARE NOT DONE FOR |
| | WORST CASE SCENARIO BUT PAGE 2 OF 4 INDICATES THAT THE |
| | BUILDING WAS ROTATED 45 DEGREES. ENERGY CALCULATIONS |
| | NEED TO BE DONE FOR THE ACTUAL ORIENTATION OF THE |
| | BUILDING. THEY CAN NOT BE ROTATED. REVISE AS REQUIRED. |
| | SEC. R103.2 FBC-ENERGY CONSERVATION, 5TH EDITION |
| | (2014). |
| | RESPONSE; REPEAT COMMENT. NOT ADDRESSED. |
| | |
| | C) THE GARAGE FLOOR IS NOT A RAISED FLOOR. SEE PLANS |
| | AND REVISE ITEM #8 AS REQUIRED. SEC. R103.2 FBC-ENERGY |
| | CONSERVATION, 5TH EDITION (2014). |
| | |
| | D) REVISE WALL INFORMATION ON ITEM #9. ACCORDING TO |
| | PLANS THE EXISTING STRUCTURE IS CONCRETE BLOCK |
| | CONSTRUCTION NOT WOOD FRAMED CONSTRUCTION. AND, THE |
| | OPENINGS LIKE THE EXISTING GARAGE DOOR OPENING IS |
| | CLOSED WITH WOOD FRAMED CONSTRUCTION. REVISE AS |
| | REQUIRED. PROVIDE INFORMATION FOR THE TWO TYPES OF |
| | WALLS TO MATCH PLANS. SEC. R103.2 FBC-ENERGY |
| | CONSERVATION, 5TH EDITION (2014). |
| | |
| | E) REVISE "SPACES" IN FORMATION ON PAGE 2 OF 4. UNIT |
| | CAN NOT HAVE A KITCHEN. SEE ZONING COMMENTS AND REVISED |
| | PLANS. REVISE AS REQUIRED. REMOVE THE KITCHEN. SEC. |
| | R103.2 FBC-ENERGY CONSERVATION, 5TH EDITION (2014). |
| | |
| | F) THE WINDOWS INFORMATION SHOWN ON PAGE 3 OF 4 DOESN'T |
| | MATCH PLANS. REVISE THE BUILDING ORIENTATION, TOTAL |
| | SQUARE FOOTAGE AND OVERHANG DEPTH AND SEPARATION TO |
| | MATCH PLANS. SEC. R103.2 FBC-ENERGY CONSERVATION, 5TH |
| | EDITION (2014). |
| | RESPONSE: REPEAT COMMENT. NOT ADDRESSED. |
| | |
| | G) BUILDER NEEDS TO COMPLETE THE EPL DISPLAY CARD. SEC. |
| | R405.4.3 FBC-ENERGY CONSERVATION, 5TH EDITION (2014). |
| | RESPONSE; REPEAT COMMENT. NOT ADDRESSED. |
| | |
| | 3- PROVIDE A/C MANUFACTURER'S SPECS FOR 18 SEER A/C |
| | UNIT AS SPECIFIED ON THE ENERGY CALCULATIONS. SEC. |
| | R103.2 FBC-ENERGY CONSERVATION, 5TH EDITION (2014). |
| | |
| | ****PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH |
| | COMMENT TO EXPEDITE THE REVIEW PROCESS. |
| | ****PLEASE INSERT ANY REVISED DRAWING AND REMOVE OLD |
| | DRAWING. DON'T STAPLE OLD DRAWINGS. SUBMITT OLD |
| | DRAWINGS FOR REFERENCE. |
| | |