| Date |
Text |
| 2016-09-16 18:49:11 | RESIDENTIAL (R3) CHANGE OF USE/ALTERATION BUILDING |
| | REVIEW COMMENTS. |
| | CODE: FBC 5TH EDITION (2014). |
| | |
| | 1- PROVIDE ENERGY CALCULATIONS (2 COPIES) AS REQUIRED |
| | BY SEC. R101.4.3 FBC-ENERGY CONSERVATION, 5TH EDITION |
| | (2014). |
| | NOTE: NEED ENERGY CALCULATIONS FOR EACH SEPARATE |
| | STRUCTURE. |
| | |
| | 2- BRING PLANS TO PALM BEACH COUNTY (2300 N. JOG RD.) |
| | FOR IMPACT FEES ASSESSMENT. BRING BACK COUNTY STAMPED |
| | PLANS AND COPY OF PAID RECEIPT IF FEES ARE DUE. COUNTY |
| | IMPACT FEE ORDINANCE OF THE UNIFIED LAND DEVELOPMENT |
| | CODE. |
| | |
| | 3- SCOPE OF WORK ON SHEET A-1 CALLS FOR "REPAIR OF 3 |
| | EXISTING FIRE DAMAGED TRUSSES PER ROOF PLAN. PROVIDE |
| | COMPLETE DETAILS AND SPECIFICATIONS FOR THE TRUSSES |
| | REPAIRS. SEC. R301.1 FBC-RESIDENTIAL, 5TH EDITION |
| | (2014). |
| | |
| | 4- WINDOW SCHEDULE ON SHEET A-2: WINDOWS #3 AND #4 |
| | DON'T COMPLY WITH EGRESS REQUIREMENTS. REVISE STATEMENT |
| | SPECIFYING "SINGLE HUNG EGRESS SIZED". SEC. R310 |
| | FBC-RESIDENTIAL. |
| | |
| | 5- VALUATION DECLARED IN THE PERMIT IS TOO LOW BASED ON |
| | THE SCOPE OF WORK SHOWN ON PLANS. VALUATION TO INCLUDE |
| | ALL LABOR, MATERIALS, CONTRACTOR'S OVERHEAD AND PROFIT |
| | AND ALL DESIGN PROFESSIONAL FEES AS REQUIRED BY SEC. |
| | 109.3 CITY AMENDMENTS. REVISE VALUATION AS REQUIRED. |
| | |
| | 6- PROVIDE PRODUCT APPROVAL ( 2 COPIES) AS REQUIRED BY |
| | FAC 61G20-3.002(33) FOR: |
| | A) PLASTIC SOFFIT VENT AS SPECIFIED ON THE TYPICAL WALL |
| | SECTION ON SHEET D1. |
| | |
| | B) ALL SIMPSON STRUCTURAL CONNECTORS SPECIFIED ON |
| | DETAILS SUBMITTED. |
| | |
| | 7- ARCHITECT OF RECORD TO REVIEW AND APPROVE IN WRITING |
| | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS |
| | (INCLUDING THE ONES ALREADY SUBMITTED) AS REQUIRED BY |
| | SEC. 107.3.4.1 CITY AMENDMENTS. |
| | |
| | ***PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH |
| | COMMENT TO EXPEDITE THE REVIEW PROCESS. |
| | ***PLEASE INSERT ANY REVISED DRAWING AND REMOVE OLD |
| | DRAWING. DON'T STAPLE OLD DRAWINGS. SUBMIT OLD DRAWINGS |
| | FOR REFERENCE. |
| | |
| | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT |
| | JULIO GOMEZ |
| | COMMERCIAL COMBINATION PLANS EXAMINER |
| | DEVELOPMENT SERVICES DEPARTMENT |
| | (561)805-6712 |
| | [email protected] |