| Date |
Text |
| 2016-08-23 08:57:03 | BUILDING PLAN REVIEW |
| | 2014 FLORIDA BUILDING CODE |
| | |
| | CHRISTOPHER S. THROOP, C.B.O. |
| | BUILDING PLANS EXAMINER ? PX3169 |
| | CONSTRUCTION SERVICES DIVISION |
| | DEVELOPMENT SERVICES DEPARTMENT |
| | TEL: 561-805-6726 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |
| | 1ST REVIEW |
| | ACTION: DENIED |
| | DATE: 8/23/16 |
| | |
| | 1. CONFLICT BETWEEN VALUE OF CONTRACT $24,241 AND |
| | STATED VALUE ON APPLICATION $19,241. PLEASE RECONCILE. |
| | 2. PROVIDE POOL BARRIER PER FBC R 4502.17.1 |
| | |
| | [A] 109.3 BUILDING PERMIT VALUATIONS. |
| | THE APPLICANT FOR A PERMIT SHALL PROVIDE AN ESTIMATED |
| | PERMIT VALUE AT TIME OF APPLICATION. PERMIT VALUATIONS |
| | SHALL INCLUDE TOTAL VALUE OF WORK, INCLUDING MATERIALS |
| | AND LABOR, FOR WHICH THE PERMIT IS BEING ISSUED, SUCH |
| | AS ELECTRICAL, GAS, MECHANICAL, PLUMBING EQUIPMENT AND |
| | PERMANENT SYSTEMS. IF, IN THE OPINION OF THE BUILDING |
| | OFFICIAL, THE VALUATION IS UNDERESTIMATED ON THE |
| | APPLICATION, THE PERMIT SHALL BE DENIED, UNLESS THE |
| | APPLICANT CAN SHOW DETAILED ESTIMATES TO MEET THE |
| | APPROVAL OF THE BUILDING OFFICIAL. FINAL BUILDING |
| | PERMIT VALUATION SHALL BE SET BY THE BUILDING OFFICIAL. |
| | |
| | R4502.17.1 OUTDOOR SWIMMING POOLS. |
| | OUTDOOR SWIMMING POOLS SHALL BE PROVIDED WITH A BARRIER |
| | COMPLYING WITH SECTIONS R4501.17.1.1 THROUGH |
| | R4501.17.1.14. |
| | |
| | R4501.17.1.1 |
| | THE TOP OF THE BARRIER SHALL BE AT LEAST 48 INCHES |
| | (1219 MM) ABOVE GRADE, MEASURED ON THE SIDE OF THE |
| | BARRIER WHICH FACES AWAY FROM THE SWIMMING POOL. THE |
| | MAXIMUM VERTICAL CLEARANCE BETWEEN GRADE AND THE BOTTOM |
| | OF THE BARRIER SHALL BE 2 INCHES (51 MM) MEASURED ON |
| | THE SIDE OF THE BARRIER WHICH FACES AWAY FROM THE |
| | SWIMMING POOL. WHERE THE TOP OF THE POOL STRUCTURE IS |
| | ABOVE GRADE, THE BARRIER MAY BE AT GROUND LEVEL OR |
| | MOUNTED ON TOP OF THE POOL STRUCTURE. WHERE THE BARRIER |
| | IS MOUNTED ON TOP OF THE POOL STRUCTURE, THE MAXIMUM |
| | VERTICAL CLEARANCE BETWEEN THE TOP OF THE POOL |
| | STRUCTURE AND THE BOTTOM OF THE BARRIER SHALL BE 4 |
| | INCHES (102 MM). |
| | |
| | |