2016-08-29 16:34:261ST REVIEW: FBC 2014 5TH ED. RESIDENTIAL
  
 IT IS NOTED THAT A SEPARATE ELECTRICAL PERMIT IS ISUED
 16061642 & THAT PER FBC- 107.3.5.3 ? SMOKE DETECTORS
 PURSUANT TO FBC-R 314.3.1 AS REQUIRED FOR NEW
 DWELLINGS, AND PER
 FBC-R 315.1 ? CARBON MONOXIDE ALARMS WITHIN 10 FEET OF
 EACH SLEEPING ROOM WILL BE PROVIDED AS APPLICABLE.
  
 PLEASE SPECIFY THE LEVEL OF ALTERATION FOR THE PROPOSED
 WORK AS CLASSIFIED IN FBC-EXISTING BUILDING. FOR EASE
 OF DETERMINING COMPLIANCE WITH FBC R308.4.5, SHOW ANY
 WINDOWS/GLAZING, EXISTING OR PROPOSED IN THE LOCATION
 ADJACENT TO THE BATHTUB.
  
 FBC R308.4.5 GLAZING AND WET SURFACES.
 GLAZING IN WALLS, ENCLOSURES OR FENCES CONTAINING OR
 FACING HOT TUBS, SPAS, WHIRLPOOLS, SAUNAS, STEAM ROOMS,
 BATHTUBS, SHOWERS AND INDOOR OR OUTDOOR SWIMMING POOLS
 WHERE THE BOTTOM EXPOSED EDGE OF THE GLAZING IS LESS
 THAN 60 INCHES (1524 MM) MEASURED VERTICALLY ABOVE ANY
 STANDING OR WALKING SURFACE SHALL BE CONSIDERED A
 HAZARDOUS LOCATION. THIS SHALL APPLY TO SINGLE GLAZING
 AND ALL PANES IN MULTIPLE GLAZING.
  
 EXCEPTION: GLAZING THAT IS MORE THAN 60 INCHES (1524
 MM), MEASURED HORIZONTALLY AND IN A STRAIGHT LINE, FROM
 THE WATER?S EDGE OF A BATHTUB, HOT TUB, SPA, WHIRLPOOL,
 OR SWIMMING POOL.
  