| Plan Review Notes For Permit 16080090 |
| Permit Number |
16080090 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2016-08-29 16:34:26 | 1ST REVIEW: FBC 2014 5TH ED. RESIDENTIAL | | | | | | IT IS NOTED THAT A SEPARATE ELECTRICAL PERMIT IS ISUED | | | 16061642 & THAT PER FBC- 107.3.5.3 ? SMOKE DETECTORS | | | PURSUANT TO FBC-R 314.3.1 AS REQUIRED FOR NEW | | | DWELLINGS, AND PER | | | FBC-R 315.1 ? CARBON MONOXIDE ALARMS WITHIN 10 FEET OF | | | EACH SLEEPING ROOM WILL BE PROVIDED AS APPLICABLE. | | | | | | PLEASE SPECIFY THE LEVEL OF ALTERATION FOR THE PROPOSED | | | WORK AS CLASSIFIED IN FBC-EXISTING BUILDING. FOR EASE | | | OF DETERMINING COMPLIANCE WITH FBC R308.4.5, SHOW ANY | | | WINDOWS/GLAZING, EXISTING OR PROPOSED IN THE LOCATION | | | ADJACENT TO THE BATHTUB. | | | | | | FBC R308.4.5 GLAZING AND WET SURFACES. | | | GLAZING IN WALLS, ENCLOSURES OR FENCES CONTAINING OR | | | FACING HOT TUBS, SPAS, WHIRLPOOLS, SAUNAS, STEAM ROOMS, | | | BATHTUBS, SHOWERS AND INDOOR OR OUTDOOR SWIMMING POOLS | | | WHERE THE BOTTOM EXPOSED EDGE OF THE GLAZING IS LESS | | | THAN 60 INCHES (1524 MM) MEASURED VERTICALLY ABOVE ANY | | | STANDING OR WALKING SURFACE SHALL BE CONSIDERED A | | | HAZARDOUS LOCATION. THIS SHALL APPLY TO SINGLE GLAZING | | | AND ALL PANES IN MULTIPLE GLAZING. | | | | | | EXCEPTION: GLAZING THAT IS MORE THAN 60 INCHES (1524 | | | MM), MEASURED HORIZONTALLY AND IN A STRAIGHT LINE, FROM | | | THE WATER?S EDGE OF A BATHTUB, HOT TUB, SPA, WHIRLPOOL, | | | OR SWIMMING POOL. | | | | | | STEVEN KENNEDY, CBO | | | CHIEF PLANS EXAMINER | | | (561) 805-6710 | | | [email protected] | | | |
|