2016-08-24 05:33:041) SHT. A4 - THE LENGTH OF THE TOILET COMPARTMENTS
 SHALL COMPLY WIYH 2014 FPC SEC. 405.3.1.
 2) SHT. A4 - TOILET COMPARTMENTS IN GANG RESTROOMS -
 DOORS SHALL NOT SWING INTO THE CLEAR FLOOR SPACE FOR
 ANY FIXTURE PER THE 2014 FAC SEC.603.2.3.
 3) SHT. A4 - THE GRAB BARS SHALL BE MEASURED FROM THE
 FINISH FLOOR TO THE TOP OF THE GRIPPING SURFACE PER
 2014 FAC SEC. 609.4.
 4) SHT. A4 - THE GRAB BAR BEHIND THE WATER CLOSET SHALL
 COMPLY WITH FIGURE 604.5.2 OF THE 2014 FAC & SEC.
 604.5.2.
 5) THE TOILET PAPER DISPENSER SHALL BE LOCATED 7-9
 INCHES FROM THE FRONT OF THE WATER CLOSET TO THE
 CENTERLINE OF THE DISPENSER. 22014 FAC SEC. 604.7.
 6) SHT. A4 - PLEASE NUMBER THE DETAILS. FBC 107.2.1.
 7) SHT. P3.1 NOTE #4 REFERS TO SHT. P5.1 FOR DETAILS OF
 HW, CW & HWR BUT P5.1 SHOWS PIPE SUPPORT. CLARIFY.
  
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 PLUMBING PLAN REVIEW
 561-805-6692
 [email protected]
  