| Date |
Text |
| 2016-08-31 07:33:24 | BUILDING PLAN REVIEW |
| | W. P. B. PERMIT: 16071099 |
| | ADD: 501 FERN ST. SUITE #102 |
| | CONT: JOHN ROSSI CONSTRUCTION |
| | TEL: 561-659-5505 |
| | E-MAIL: ROSSI:[email protected] |
| | |
| | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| | ADMINISTRATION |
| | |
| | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. |
| | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND |
| | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE |
| | FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 1ST REVIEW |
| | DATE: THURS. AUGUST 04/ 2016 |
| | ACTION: DENIED |
| | |
| | 1-6A) COMPLIED. |
| | |
| | 6B) SHEET LS 1 AND A.3 SHOW A LOBBY BUT NO INFORMATION |
| | IS GIVEN ON THE STAIRS, RAMP HAND RAILS NOR THE |
| | GUARDRAILS. PLEASE NOTE THE CITY GAVE A ONE TIME USE ON |
| | A TEMPORARY EVENT PERMIT FOR THESE ITEMS, BUT IT WAS A |
| | ONE TIME EVENT. UNDER THAT ONE TIME EVENT THERE WERE NO |
| | LOADS GIVEN. |
| | 2014 FBC-B 1009.7.2 RISER HEIGHT AND TREAD DEPTH. |
| | 1009.3.1.1 MATERIALS |
| | 1010.1 RAMPS SCOPE |
| | 1010.3 SLOPE |
| | 1010.5 VERTICAL RISE |
| | 1010.7 LANDINGS. |
| | 1010.7.4 CHANGE IN DIRECTION |
| | 1010.8 RAMP CONSTRUCTION |
| | 1010.9 HANDRAILS. & SECTION 1012 |
| | 1010.11 GUARDS. & SECTION 1013. |
| | TABLE 1607.1 LIVE LOADS STAIRS AND RAMPS |
| | 1028.2 ASSEMBLY MAIN EXIT. |
| | 1028.3 ASSEMBLY OTHER EXITS. |
| | 2014 FBC-ACCESS. CODE SECTION 405. RAMPS / STAIRS 504. |
| | 216.1. SIGNS SHALL BE PROVIDED IN ACCORDANCE WITH 216 |
| | AND SHALL COMPLY WITH 703. |
| | 216.9.2 DIRECTIONAL SIGNS. |
| | |
| | 6C) SHEET A.4 DETAIL A DOES NOT INDICATE WHAT THE |
| | MATERIALS THIS RAMP IS MADE FROM NOR THE LIVE LOADS FOR |
| | THE RAMP NOR THE HANDRAIL SYSTEM. 1607.8.1.1 |
| | CONCENTRATED LOAD. HANDRAILS AND GUARDS SHALL ALSO BE |
| | DESIGNED TO RESIST A CONCENTRATED LOAD OF 200 POUNDS |
| | (0.89 KN) IN ACCORDANCE WITH SECTION 4.5.1 OF |
| | ASCE 7. |
| | |
| | |
| | 7-9) COMPLIED. |
| | |
| | 10) WHEN RESUBMITTING PLANS PLEASE INDICATE THE |
| | REVISION & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES |
| | AS NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL |
| | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE |
| | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION |
| | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO |
| | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| | COOPERATION. |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | CONSTRUCTION SERVICES DIVISION |
| | DEVELOPMENT SERVICES DEPARTMENT |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |