Notes
Date Text
2016-08-18 14:32:021ST REVIEW
  
  
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER LL
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES
 BUILDING DIVISION
 561-805-6711
 [email protected]
  
  
 PLUMBING COMMENTS:
  
 1. PROVIDE DETAILED SCOPE OF PLUMBING WORK BEING DONE
 UNDER THIS PERMIT IF THERE IS NO PLUMBING WORK BEING
 DONE PUT A NOTE ON THE PLAN STATING THAT. WPB AMEND TO
 FBC 107.2.1
 2. THE CHANGE OF OCCUPANCY REQUIRES COMPLIANCE WITH FBC
 PL TABLE 403.1 IF THIS IS AN A2 WITH A OCCUPANT LOAD OF
 471 IT WILL REQUIRE 6 WATER CLOSETS FOR MEN AND 9 FOR
 WOMEN 4 LAVATORY'S FOR BOTH SEXES . IF THE OCCUPANT
 LOAD IS 225 IT WILL REQUIRE 3 WATER CLOSETS FOR MEN 6
 FOR WOMEN AND 2 LAVATORY'S FOR BOTH SEXES.
 DUE TO THE DEFICIENCIES OF THIS PLAN A COMPLETE AND
 THOROUGH REVIEW CANNOT BE DONE AT THIS TIME. UPON
 RESUBMITTAL THERE MAYBE ADDITIONAL COMMENTS.