| 2017-08-10 12:57:06 | ****PROVISOS**** |
| | |
| | SAMANTHA HILL |
| | BUILDING PLANS EXAMINER |
| | [email protected] |
| | 561-805-6724 |
| | |
| | FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014) |
| | FBC B = FBC BUILDING |
| | FBC EB = FBC EXISTING BUILDING |
| | FBC A = FBC ACCESSIBILITY |
| | FBC EC = FBC ENERGY CONSERVATION |
| | |
| | A. SEPARATE PERMITS REQUIRED FOR SITE AMENITIES, POOL, |
| | POOL DECK, FENCING, PAVING, SIDEWALKS, FIRE ALARM, FIRE |
| | SPRINKLER, FIRE UNDERGROUND, PARKING LOT & STRIPING, |
| | TEMPORARY TRAILER, CONSTRUCTION OFFICES, SIGNS. |
| | SEPARATE PLANS, PERMITS, REVIEWS, AND FEES REQUIRED. |
| | |
| | B. WORK AREAS TO COMPLY WITH FBC ACCESSIBILITY (FBC A |
| | 902.1 ADVISORY, ABA) PER ARCHITECT |
| | |
| | C. FLOORING ACOUSTICAL INSULATION REQUIRED BY FBC 1207 |
| | IS TO COMPLY WITH THE FOLLOWING: |
| | |
| | (1) FBC 1207.2, FLOOR/CEILING ASSEMBLIES SEPARATING |
| | DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR |
| | SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS |
| | (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR AIR |
| | BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E 90. |
| | PROVIDE A COPY OF THE TEST REPORT (WITHOUT A DROPPED |
| | GYPSUM CEILING ASSEMBLY). |
| | (2) FBC 1207.3, FLOOR/CEILING ASSEMBLIES BETWEEN |
| | DWELLING UNITS OR BETWEEN A DWELLING UNIT AND A PUBLIC |
| | OR SERVICE AREA WITHIN THE STRUCTURE SHALL HAVE AN |
| | IMPACT INSULATION CLASS (IIC) RATING OF NOT LESS THAN |
| | 50 (45 IF FIELD TESTED) WHEN TESTED IN ACCORDANCE WITH |
| | ASTM E 492. PROVIDE A COPY OF THE TEST REPORT (WITHOUT |
| | A DROPPED GYPSUM CEILING ASSEMBLY). |
| | (3) FBC 720.2, FLAME SPREAD INDEX OF NOT MORE THAN 25 |
| | AND SMOKE DEVELOPED INDEX OF NOT MORE THAN 450 |
| | REQUIRED. PROVIDE TEST DATA IN ACCORDANCE WITH ASTM E |
| | 84 OR UL 723. |
| | |
| | TEST REPORTS, REVIEWED BY DESIGNER OF RECORD, ARE TO BE |
| | SUBMITTED PRIOR TO INSTALLATION. |
| | |
| | D. PRODUCT APPROVALS ARE REQUIRED FOR ALL COMPONENTS |
| | AND CLADDING, FBC 1609. PRODUCT APPROVALS, REVIEWED BY |
| | DESIGNER OF RECORD, ARE TO BE SUBMITTED PRIOR TO |
| | INSTALLATION. COMPONENTS AND CLADDING ARE TO COMPLY |
| | WITH THE DESIGN PRESSURES SHOWN ON SHEET S0. THE |
| | OPTIONS SELECTED ARE TO BE MARKED ON THE PRODUCT |
| | APPROVALS PRIOR TO SUBMITTAL. |
| | |
| | E. A SEPARATE ROOF PERMIT IS REQUIRED. THE PRODUCT |
| | APPROVAL REVIEWED BY DOR IS TO BE SUBMITTED PRIOR TO |
| | INSTALLATION. THE APPROVED ASSEMBLY PROPOSED IS TO BE |
| | INDICATED AND ENGINEERING, IF APPLICABLE, SUBMITTED. |
| | |
| | F. CIVIL PAGES WERE NOT REVIEWED BY BUILDING; PAVING |
| | WILL BE REVIEWED UNDER A SEPARATE PERMIT. |
| | |
| | G. FAIR HOUSING COMPLIANCE; SHEET A1.00 HAS A NOTE: |
| | 1 BED 75 UNITS WITH TYPE B BATH |
| | 2 BED 50 UNITS WITH ONE TYPE A AND ONE TYPE B PER FHA |
| | |
| | H. SHORING/RESHORE PLANS AND ENGINEERING REVIEWED BY |
| | CONTRACTOR AND SPECIAL INSPECTOR ARE TO BE SUBMITTED, |
| | REVIEWED AND ISSUED (AS A "SUBMITTAL" TO THE BUILDING |
| | DIVISION) PRIOR TO INSTALLATION. NO AFFECTED WORK TO |
| | COMMENCE WITHOUT THE SHORING/RESHORE ENGINEERING ON |
| | SITE, REVIEWED AND ISSUED BY BUILDING DIVISION. |
| | |
| | I. A CONSTRUCTION GUARDRAIL DETAIL, PREPARED BY A |
| | DESIGN PROFESSIONAL LICENSED UNDER FS471 OR FS481, IS |
| | REQUIRED TO BE SUBMITTED, REVIEWED, AND ISSUED BY THE |
| | CITY. SUBJECT TO FIELD INSPECTOR'S DISCRETION, THIS MAY |
| | BE ACCEPTED IN THE FIELD AT TIME OF INSPECTION. |
| | |
| | J. FILES SUBMITTED UNDER PERMIT APPLICATION #16071058 |
| | WERE REVIEWED. PER APPLICANT, THE SAME PLANS WERE |
| | SUBMITTED FOR PERMITS 16070880, 16070916, 16071059. THE |
| | PLANS APPEAR IDENTICAL. ANY (BUILDING REVIEWED) |
| | DISCREPANCIES ARE SUPERSEDED BY THE PLANS REVIEWED |
| | UNDER 16071058. |
| | |
| | K. REGARDING THE STRUCTURAL CALCULATIONS: |
| | |
| | PAGE 35, F27 SHOWS A 4TH FLOOR WOOD SLAB; CLARIFY. |
| | PAGE 11 OF 109 AUTO WIND LOAD CALCULATION SHOWS BASIC |
| | WIND SPEED AS 136MPH, BUT PAGE 9 OF 63 IS 170MPH. ONE |
| | APPEARS TO BE VASD, THE OTHER APPEARS TO BE VULT, BUT I |
| | CANNOT FIND WHERE IT STATES THIS, AND IT IS NOT CLEAR |
| | WHY THEY WOULD BE DONE DIFFERENTLY. |
| | PAGE 30 OF 109, TABLE 4.5 STEEL FRAME SUMMARY, ROOF |
| | LABEL C46 HAS A STATUS OF "WARNING: SEE MESSAGE". I WAS |
| | UNABLE TO LOCATE THE MESSAGE IN THE 833 PAGE DOCUMENT. |
| | PLEASE PROVIDE THE WARNING NOTED. |
| | |
| | |
| | ****************************************** |
| | BUILDING DATA FOR CO & REPORTING (INTERNAL USE ONLY) |
| | |
| | USC-404 TYPE 105 - NEW:RES FIVE OR MORE UNITS |
| | SQUARE FEET - 4964 |
| | |
| | CONSTRUCTION TYPE: 14-V-B - 5TH ED TYPE V-B |
| | UNITS: 6 |
| | FLOORS: 1 |
| | BEDROOMS: 8 |
| | ROOMS: 22 |
| | SQ FT LIVABLE: 4964 |
| | SQ FT FOOTPRINT: 4964 |
| | SQ FT ROOF: 4964 |
| | |
| | SETBACKS FRONT (USE THIS TO ENTER VERTICAL DATUM IF |
| | KNOWN): |
| | SETBACKS BACK (USE THIS TO ENTER FIRST FLOOR IF KNOWN): |
| | XX.XX |
| | SETBACKS LEFT (USE THIS TO ENTER SECOND FLOOR IF KNOWN: |
| | XX.XX |
| | OCC LOAD: 26 |
| | PROP USE: APARTMENT |
| | SPRINKLER SYS? Y |
| | SPRK REQ'D? Y |
| | BATHRMS: 8 |
| | |
| | BLDG CODE: FL 2014 |
| | OCC CLASS: 5TH ED R-2 |
| | |