| Plan Review Notes For Permit 16070942 |
| Permit Number |
16070942 |
|
| Review Stop |
P |
| Sequence Number |
3 |
|
| Notes |
| Date |
Text |
| 2016-10-14 09:16:55 | 3RD-REVIEW | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER LL | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES | | | BUILDING DIVISION | | | 561-805-6711 | | | [email protected] | | | | | | PLUMBING COMMENTS: | | | | | | IT DOES NOT APPEAR THAT THE PREVIOUS COMMENTS DATED | | | 9/26/16 WERE ADDRESSED THE RESPONSE LETTER PROVIDED WAS | | | FROM COMMENTS DATED 8/23/16 PLEASE CLARIFY. PER WPB | | | AMEND TO FBC 107.2.1 | | | | | | 1. SHT. G-004.00 FIG.#3 CLEARANCE FOR TOILET SHOULD | | | SHOW CLEARLY 60" MEASURED FROM SIDE WALL . THE PLAN | | | SHOWS 60" WITH ARROW POINTING TOWARD BACK WALL OF | | | TOILET PLEASE CLARIFY. PER WPB AMEND TO FBC 107.2.1 | | | | | | 2. SHT.G-004.00 FIG. #5 SHOWS HEIGHT OF LAV AT 34" MIN | | | IT SHALL SHOW 34" MAX NOT MIN. PET FBC ACC 606.3 | | | | | | 4. 3ND REQUEST PREVIOUS COMMENT DOES NOT COMPLY. SHT. | | | A205 - DETAIL #5 - THE COUNTERTOP SHALL BE A MAXIMUM OF | | | 34 INCHES ABOVE THE FINISH FLOOR. 2014 FAC SEC.606.3. | | | | | | 5. 3ND REQUEST SHT. M2.2 - DRAWING NOTE #2 - THE | | | CONDENSATE SHALL NOT DISCHARGE TO THE SANITARY SYSTEM | | | PER WPB CODE OF ORDINANCES CHAPT. 90, ART.III, SEC. | | | 90-126 (5). | | | A) NOTE ON SHT. M-2.2 IS UNCLEAR IT INDICATES DISCHARGE | | | ON CONDENSATE INTO MOP SINK WHICH IS SANITARY DRAINAGE, | | | THEN IT SAYS CONDENSATE SHALL NOT DISCHARGE INTO | | | SANITARY PLEASE CLARIFY. | | | B) PROVIDE CONDENSATE RISER DIAGRAM SHOWING DISCHARGE | | | INTO STORM DRAINAGE. PER WPB AMEND TO FBC 107.2.1 | | | | | | | | | |
|