2016-08-23 06:41:141)DRAWING G-004.00 - THE FOLLOWING THREE COMMENTS APPLY
 TO THE SAME SHEET.
 FIG. #2 - THE HEIGHT OF THE GRAB BAR SHALL BE MEASURED
 FROM THE FINISH FLOOR TO THE TOP OF THE GRIPPING
 SURFACE PER THE 2014 FAC SEC. 609.4.
 FIG.#3 - THE CLEAR FLOOR SPACE FOR THE WATEER CCLOSET
 SHALL CCOMPLY WITH THE FAC SEC. 604.3.
 FIG.#5 - THE MAXIMUM HEIGHT TO THE TOP OF THE LAVATORY
 SHALL BE 34 INCHES. THE DETAIL SHOWS 29 INCHES MINIMUM.
 FAC SEC. 606.3.
 2) THE COFFEE MACHINES, ICE MAKERS, ESPRESSO MACHINE,
 ETC. SHALL BE EQUIPPED WITH BACKFLOW PREVENTERS IN
 ACCORDANCE THE 2014 FPC SEC. 608.3, 608.16.10.
 3) PER TABLE 403.1 OF THE 2014 FPC AND THE OCCUPANT
 LOAD SHOWN ON THE PLANS THE TOTAL NUMBER OF SANITARY
 FACILITIES REQUIRED FOR THE MALES IS 5 WATER CLOSETS
 AND 4 LAVATORIES AND 5 WATER CLOSETS AND 4 LAVATORIES
 FOR THE FEMALES. INCLUDING THE EXISTING FACILITIES, THE
 SPACE IS DEFICIENT OF ONE WATER CLOSET EACH FOR THE
 MALES AND FEMALES AND TWO LAVATORIES EACH FOR THE MALES
 AND FEMALES. THE PROPOSED UNISEX TOILET ROOM CAN HELP
 SATISFY THE REQUIREMENTS FOR ONE GENDER ONLY.
 4) SHT. A205 - DETAIL #5 - THE COUNTERTOP SHALL BE A
 MAXIMUM OF 34 INCHES ABOVE THE FINISH FLOOR. 2014 FAC
 SEC.606.3.
 5) SHT. M2.2 - DRAWING NOTE #2 - THE CONDENSATE SHALL
 NOT DDISCHARGE TO THE SANITARY SYSTEM PER WPB CODE OF
 ORDINANCES CHAPT. 90, ART.III, SEC. 90-126 (5).
 6) SHT. P-2 - IDENTIFY RISERS #1 & #2 ON THE FLOOR
 PLAN.
 7) SUBMIT TWO COPIES OF THE MANUFACTURER'S
 SPECIFICATIONS FOR THE CHRONOMITE WATER HEATEER. WPB
 AMEND. TO FBC SEC. 107.2.1.
 8) VENTS OTHER THAN STACK VENTS OR VENT STACKS EXCEEDIN
 40 FEET IN DEVELOPED LENGTH SHALL BE INCREASED BY ONE
 NOMINAL PIPE SIZE FOR THE ENTIRE DEEVELOPED LENGTH OF
 THE VENT PIPE IN ACCORDANCE WITH THE 2014 FPC
 SEC.906.2.
  