| 2016-08-10 12:25:03 | BUILDING PLAN REVIEW |
| | W. P. B. PERMIT: 16070942 |
| | ADD: 525 OKEECHOBEE BLVD. SUITE # 1500 |
| | CONT: MC GOWAN BUILDERS |
| | TEL: 305-774-7100 |
| | E-MAIL: AMCMCGOWANBUILDERS.COM |
| | |
| | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| | ADMINISTRATION |
| | |
| | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. |
| | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND |
| | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE |
| | FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 1ST REVIEW |
| | DATE: WED. AUSUST 10/ 2016 |
| | ACTION: DENIED |
| | |
| | 1) SHEETSA-001.00 & A-101.00 IT APPEARS ONE OF THE |
| | ELEVATOR LOBBY DOORS ARE MISSING. THE INTERIOR DEMO |
| | PLAN 16061108 DOES NOT SHOW THIS SET OF DOORS BEING |
| | REMOVED. SHEET A-001.00 UNDER THE HEADING PROJECT |
| | INFORMATION DOES NOT MENTION THE REQUIREMENT FOR |
| | ELEVATOR LOBBY DOORS (FBC-B 713.14.1) OR THE EXCEPTIONS |
| | THAT CAN BE TAKEN. PLEASE PROVIDE CODE COMPLIANCE. |
| | |
| | 2) SHEETSA-001.00 & A-101.00 BOTH FLOOR PLANS 1/8 INCH |
| | SCALE, CODE COMPLIANCE FOR MANEUVERING CLEARANCES 18 |
| | INCHES LATCH SIDE OF THE DOOR, FBC-ACCESSIBILTY CODE |
| | CAN NOT BE VERIFIED FOR THE FOLLOWING DOORS. 15-015, |
| | 15-016, 15-035, 15-060, 15-065, 15-075 & 15-076. |
| | |
| | 3) SHEETSA-001.00 & A-101.00 BOTH FLOOR PLANS BOTH |
| | INDICATE THE USE OF HORIZONTAL SLIDDING DOORS WITH AN |
| | AREA WITH AN OCCUPANT LOAD GREATER THAN 10, SEE DOOR |
| | LOCATIONS 15-074 & 15-081. 2014 FBC-B 1008.1.2 |
| | EXCEPTION # 9. IN OTHER THAN GROUP H OCCUPANCIES, |
| | MANUALLY OPERATED HORIZONTAL SLIDING DOORS ARE |
| | PERMITTED IN A MEANS OF EGRESS FROM SPACES WITH AN |
| | OCCUPANT LOAD OF 10 OR LESS. |
| | |
| | 4) SHEET G-004.00 ACCESSIBLE ELEMENTS & MEASUREMENTS: |
| | 4A) FIGURE 2 SHOWS THE GRAB BAR BEING DIMENSIONED FROM |
| | THE CENTERLINE, PLEASE NOTE UNDER THE 2014 |
| | ACCESSIBILITY CODE SECTION 609.4 THE DIMENSIONS ARE |
| | TAKEN FROM FINISH FLOOR TO THE TOP OF THE GRASPING |
| | SURFACE. |
| | |
| | 4B) FIGURE 3 THE 60 INCH CLEAR FLOOR SPACE FOR THE |
| | WATER CLOSET INCLUDES THE LAVATORY. PLEASE REVIEW THE |
| | 2014 ACCESSIBILITY CODE SECTIONS; |
| | 604.3.1 SIZE. CLEARANCE AROUND A WATER CLOSET SHALL BE |
| | 60 INCHES (1525 MM) MINIMUM MEASURED PERPENDICULAR FROM |
| | THE SIDE WALL AND 56 INCHES (1420 MM) MINIMUM MEASURED |
| | PERPENDICULAR FROM THE REAR WALL. |
| | |
| | 604.3.2 OVERLAP. THE REQUIRED CLEARANCE AROUND THE |
| | WATER CLOSET SHALL BE PERMITTED TO OVERLAP THE WATER |
| | CLOSET, ASSOCIATED GRAB BARS, DISPENSERS, SANITARY |
| | NAPKIN DISPOSAL UNITS, COAT HOOKS, SHELVES, ACCESSIBLE |
| | ROUTES, CLEAR FLOOR SPACE AND CLEARANCES REQUIRED AT |
| | OTHER FIXTURES, AND THE TURNING SPACE. NO OTHER |
| | FIXTURES OR OBSTRUCTIONS SHALL BE LOCATED WITHIN THE |
| | REQUIRED WATER CLOSET CLEARANCE. |
| | |
| | 4C) BOTH THE WALL TELEPHONE, INTERCOM AND THERMOSTATE |
| | WILL NEED TO BE IN THE REACH RANGES AND OPERABLE PARTS. |
| | 2014 FBC-ACCESSIBILITY CODE309.2 CLEAR FLOOR SPACE. A |
| | CLEAR FLOOR OR GROUND SPACE COMPLYING WITH 305 SHALL BE |
| | PROVIDED. 309.3 HEIGHT. OPERABLE PARTS SHALL BE PLACED |
| | WITHIN ONE OR MORE OF THE REACH RANGES SPECIFIED IN |
| | 308. |
| | |
| | 4D) DEADBOLT IS LISTED AT A HEIGHT OF DEAD BOLT IS |
| | LISTED AT 5 FEET. WILL NEED TO COMPLY WITH 2014 |
| | FBC-ACCESSIBILITY CODE309.2 CLEAR FLOOR SPACE. A CLEAR |
| | FLOOR OR GROUND SPACE COMPLYING WITH 305 SHALL BE |
| | PROVIDED. 309.3 HEIGHT. OPERABLE PARTS SHALL BE PLACED |
| | WITHIN ONE OR MORE OF THE REACH RANGES SPECIFIED IN |
| | 308. |
| | |
| | 4E) THERE ARE NO DETAILS FOR ACCESSIBLE SIGNAGE |
| | COMPLIANCE: ACCESS. CODE 703.1 SIGNS SHALL COMPLY WITH |
| | 703. WHERE BOTH VISUAL AND TACTILE CHARACTERS ARE |
| | REQUIRED, EITHER ONE SIGN WITH BOTH VISUAL AND TACTILE |
| | CHARACTERS, OR TWO SEPARATE SIGNS, ONE WITH VISUAL, AND |
| | ONE WITH TACTILE CHARACTERS, SHALL BE PROVIDED. |
| | |
| | 703.2 RAISED CHARACTERS. RAISED CHARACTERS SHALL COMPLY |
| | WITH 703.2 AND SHALL BE DUPLICATED IN BRAILLE COMPLYING |
| | WITH 703.3. RAISED CHARACTERS SHALL BE INSTALLED IN |
| | ACCORDANCE WITH 703.4. |
| | |
| | 5) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION |
| | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS |
| | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL |
| | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE |
| | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION |
| | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO |
| | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| | COOPERATION. |
| | |