2016-11-09 08:27:12BUILDING PLAN REVIEW
 W. P. B. PERMIT: 16070909
 ADD: 5112 GEORGIA AVE.
 CONT: TD GONE BUILDING
 TEL: 561-436-4047
 E-MAIL; [email protected]
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE.
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING.
  
 3RD REVIEW
 DATE: WED.NOV. 09 2016
 ACTION: PROVISO
  
 1) . CONTRACTOR AT OWN RISK!!!
 SHEET S1 DETAIL 3 & 4 BOTH SHOW THE USE OF A ROOF TOP
 PRESSURE TREATED 4 X 4. PLEASE NOTE PITCH PANS HAVE NOT
 BEEN USED IN THE CODE FOR SOME TIME NOW. PLEASE REVIEW
 UNDER THE 2014 FBC-B 1509.6.5 AND TABLE 1509.6.5.
 1509.6.5 MECHANICAL UNITS. ROOF MOUNTED MECHANICAL
 UNITS SHALL BE MOUNTED ABOVE THE ROOF SURFACE, OR WHERE
 ROOFING MATERIALS EXTEND BENEATH THE UNIT, ON RAISED
 EQUIPMENT SUPPORTS PROVIDING A MINIMUM CLEARANCE HEIGHT
 IN ACCORDANCE WITH TABLE 1509.6.5.
  