| Plan Review Notes For Permit 16070712 |
| Permit Number |
16070712 |
|
| Review Stop |
G |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2016-07-27 05:15:23 | 1) SUBMIT TWO COPIES OF THE GAS PLAN. WPB AMEND. TO FBC | | | SEC. 107.1. | | | 2) INDDICATE ON BOTH PLANS IF THE GAS STOVE AND OUTLET | | | ARE EXISTING AND BEING REPLACED WITH NEW PIPING OR IS | | | THIS BEING ADDED TO TO AN EXISTING GAS SYSTEM. | | | 3) IF THIS IS A NEW GAS OUTLET BEING ADDED TO AN | | | EXISTING SYSTEM, SUBMIT A COMPLETE GAS RISER SHOWING | | | ALL EXISTING GAS APPLIANCES WITH THE BTU LOAD OF EACH | | | AAPLIANCE AND THE TOTAL BTU LOAD ON THE SYSTEM, TYPE OF | | | PIPE, LONGEEST DEVELOPED LENGTH TO MOST REMOTE GAS | | | OUTLET.FGC SEC. 402. | | | 4) SUBMIT MANUF. SPECIFICATIONS SHOWING THAT THE RANGE | | | IS LISTED AND LABELED PER FGC SEC. 301. | | | | | | | | | PLUMBING PLAN REVIEW | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | 561-805-6692 | | | [email protected] | | | |
|