| 2016-11-02 08:14:55 | BUILDING PLAN REVIEW |
| | W. P. B. PERMIT: 16070634 |
| | ADD: 505 S. FLAGLER 15TH FLOOR COMMON AREAS |
| | CONT: ANDERSON ?MOORE CONSTRUCTION |
| | TEL: 561-662-1819 |
| | E-MAIL: RKENNEY@ AMCBUILD.COM |
| | |
| | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| | ADMINISTRATION |
| | |
| | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. |
| | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND |
| | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE |
| | FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 1ST REVIEW |
| | DATE: WED. AUGUST 10/ 2016 |
| | ACTION: DENIED |
| | |
| | 1) COMPLIED. |
| | |
| | 2) 2ND REQUEST. THE RESPONSE LETTER STATES SEE ATTACHED |
| | DOSPROPORTIONATE COST LETTER SHOWING THAT THE |
| | ACCESSIBLE UPGRADES MEET THE 20% MINIMUM REQUIREMENTS. |
| | NO SUCH DOCUMENT IS IN THE FILE FOLDER. ONLY THE |
| | APPLICATION AND 3 PAGES OF COMMENT |
| | RESPONSES!!!!!!!!!!!!! |
| | |
| | 1ST REVIEW COMMENTS. THIS PROJECT HAS A PERMIT VALUE OF |
| | $118,875.00 DOLLARS IN VALUE. THE CONTRACTOR WILL NEED |
| | TO SUPPLY AN ITEMIZED LIST FOR ACCESSIBLE UPGRADES |
| | WHERE UP TO 20% OF THE VALUE OF THE PROJECT, $23,775.00 |
| | DOLLARS. PLEASE REVIEW SECTION 202.4.1 DISPROPORTIONATE |
| | COST OF THE 2014 FBC-ACCESSIBILITY CODE OF THE ORDER |
| | HOW THE FUNDS ARE TO BE SPENT. |
| | 202.4.1 DISPROPORTIONATE COST. ALTERATIONS MADE TO |
| | PROVIDE AN ACCESSIBLE PATH OF TRAVEL TO THE ALTERED |
| | AREA WILL BE DEEMED DISPROPORTIONATE TO THE OVERALL |
| | ALTERATION WHEN THE COST EXCEEDS 20% OF THE COST OF THE |
| | ALTERATION TO THE PRIMARY FUNCTION AREA. COSTS THAT MAY |
| | BE COUNTED AS EXPENDITURES REQUIRED TO PROVIDE AN |
| | ACCESSIBLE PATH OF TRAVEL MAY INCLUDE: (I) COSTS |
| | ASSOCIATED WITH PROVIDING AN ACCESSIBLE ENTRANCE AND AN |
| | ACCESSIBLE ROUTE TO THE ALTERED AREA; (II) COSTS |
| | ASSOCIATED WITH MAKING RESTROOMS ACCESSIBLE, SUCH AS |
| | INSTALLING GRAB BARS, ENLARGING TOILET STALLS, |
| | INSULATING PIPES, OR INSTALLING ACCESSIBLE FAUCET |
| | CONTROLS; (III) COSTS ASSOCIATED WITH PROVIDING |
| | ACCESSIBLE TELEPHONES, SUCH AS RELOCATING THE TELEPHONE |
| | TO AN ACCESSIBLE HEIGHT, INSTALLING AMPLIFICATION |
| | DEVICES, OR INSTALLING A TEXT TELEPHONE (TTY); (IV) |
| | COSTS ASSOCIATED WITH RELOCATING AN INACCESSIBLE |
| | DRINKING FOUNTAIN. |
| | |
| | 3) COMPLIED. |
| | |
| | 4) 2ND REQUEST. THE RESPONSE LETTER STATES SEE ATTACHED |
| | DOSPROPORTIONATE COST LETTER SHOWING THAT THE |
| | ACCESSIBLE UPGRADES MEET THE 20% MINIMUM REQUIREMENTS. |
| | NO SUCH DOCUMENT IS IN THE FILE FOLDER. ONLY THE |
| | APPLICATION AND 3 PAGES OF COMMENT |
| | RESPONSES!!!!!!!!!!!!! |
| | |
| | 1ST REVIEW COMMENTS. SHEET LS1 & 15-A1.0. PLEASE |
| | PROVIDE HOW ACCESSIBLE UPGRADES WILL BE ACCOMPLISHED |
| | FOR DOORS 1501A, 1508 & 1509, PLEASE PROVIDE WHERE THE |
| | REMAINING FUNDS WILL BE SPENT FOR THE ACCESSIBLE |
| | UPGRADES UNTIL THE 20% OF THE CONTRACT PRICE HAS BEEN |
| | MET. |
| | |
| | 5) DIGITAL REVIEW. A TRANSMITTAL LETTER LISTING THE |
| | ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF |
| | THE REVISION MADE, IDENTIFYING THE SHEET OR |
| | SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL |
| | HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR |
| | ANTICIPATED COOPERATION. |
| | |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | CONSTRUCTION SERVICES DIVISION |
| | DEVELOPMENT SERVICES DEPARTMENT |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |
| | |
| | |