Plan Review Notes
Plan Review Notes For Permit 16070425
Permit Number 16070425
Review Stop B
Sequence Number 1
Notes
Date Text
2016-08-08 09:21:32BUILDING PLAN REVIEW
 W. P. B. PERMIT: 16070425
 PRIME: 15050262
 ADD: 1851 DIVISION AVE/ BLDG # III
 CONT: IV GROUP INC.
 TEL: 305-667-0222
 E-MAIL: ????????????????????
  
 2010 FLORIDA BUILDING CODE W 2010 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 1ST REVIEW
 DATE: MON. AUGUST 08/2016
 ACTION: DENIED
  
 1) BOTH THE PRIME PERMIT AND THE WINDOW/ DOOR PERMIT
 INDICATE THE JOBSITE ADDRESS OF 1851DIVISION AVE.
 WHEREAS THE PLANS PRODUCED BY CDM WINDOWS AND DOORS
 INDICATE THE ADDRESS OF 1624 DOUGLAS AVE.
 THERE IS A DISCREPANCY IN THE JOBSITE LOCATION FOR THIS
 PROJECT, IT DOESN?T MATCH THE PRIME(MASTER PERMIT).
  
 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
 CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY
 TO INDICATE THE LOCATION OF THE PROJECT. 107.2.1.3
 ADDITIONAL INFORMATION. DISCREPANCY IN PROJECT SITE
 LOCATIONS.
  
 2) THE PLANS CREATED BY CDM SHOW A SHOP DRAWING STAMP
 OF APPROVAL BUT THE SUBMITTED PRODUCT APPROVALS DO NOT
 SHOW COMPLIANCE WITH: 2010 FLORIDA BUILDING CODE W 2010
 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING
 CODE, CHAPTER 1, ADMINISTRATION 107.3.4 DESIGN
 PROFESSIONAL IN RESPONSIBLE CHARGE. THE REGISTERED
 DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE SHALL BE
 RESPONSIBLE FOR REVIEWING AND COORDINATING SUBMITTAL
 DOCUMENTS PREPARED BY OTHERS, INCLUDING PHASED AND
 DEFERRED SUBMITTAL ITEMS, FOR COMPATIBILITY WITH THE
 DESIGN OF THE BUILDING. THOSE PRODUCTS WHICH ARE
 REGULATED BY DCA RULE 9N-3SHALL BE REVIEWED AND
 APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR TO
 SUBMITTAL FOR JURISDICTIONAL APPROVAL.
  
 3) IDENTIFY GLAZING/ MULLIONS. FOR ALL PRODUCTS WITH
 GLAZING, PLEASE IDENTIFY THE OPENING WIDTH & HEIGHT,
 TYPE OF GLAZING (IN THE PRODUCT APPROVAL) , MULLION
 INFORMATION IF REQUIRED, ATTACHMENTS AND ASSOCIATE
 PRESSURES FOR EACH OPENING SIZE. 2010 FBC-B 1609.1.2
 PROTECTION OF OPENINGS, 1609.6.4.4.1 COMPONENTS &
 CLADDING.
  
 4) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION
 DEVELOPMENT SERVICES DEPARTMENT
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved