| Date |
Text |
| 2016-07-22 14:41:58 | |
| | BUILDING PLAN REVIEW |
| | 2014 FLORIDA BUILDING CODE |
| | |
| | CHRISTOPHER S. THROOP, C.B.O. |
| | BUILDING PLANS EXAMINER ? PX3169 |
| | CONSTRUCTION SERVICES DIVISION |
| | DEVELOPMENT SERVICES DEPARTMENT |
| | TEL: 561-805-6726 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |
| | 1ST REVIEW |
| | ACTION: DENIED |
| | DATE: 7/22/16 |
| | |
| | 1. PROVIDE SITE PLAN IDENTIFYING LOCATION OF STAIRS AND |
| | SET BACK FROM PROPERTY LINE. |
| | 2. PROVIDE LANDING PER FBC R311.7.6 |
| | 3. HANDRAILS SHALL COMPLY WITH FBC R311.7.8 |
| | 4. GUARDS SHALL COMPLY WITH FBC 1013 |
| | |
| | R311.7.6 LANDINGS FOR STAIRWAYS. |
| | THERE SHALL BE A FLOOR OR LANDING AT THE TOP AND BOTTOM |
| | OF EACH STAIRWAY. THE MINIMUM WIDTH PERPENDICULAR TO |
| | THE DIRECTION OF TRAVEL SHALL BE NO LESS THAN THE WIDTH |
| | OF THE FLIGHT SERVED. LANDINGS OF SHAPES OTHER THAN |
| | SQUARE OR RECTANGULAR SHALL BE PERMITTED PROVIDED THE |
| | DEPTH AT THE WALK LINE AND THE TOTAL AREA IS NOT LESS |
| | THAN THAT OF A QUARTER CIRCLE WITH A RADIUS EQUAL TO |
| | THE REQUIRED LANDING WIDTH. WHERE THE STAIRWAY HAS A |
| | STRAIGHT RUN, THE MINIMUM DEPTH IN THE DIRECTION OF |
| | TRAVEL SHALL BE NOT LESS THAN 36 INCHES (914 MM). |
| | |
| | R311.7.8 HANDRAILS. |
| | HANDRAILS SHALL BE PROVIDED ON AT LEAST ONE SIDE OF |
| | EACH CONTINUOUS RUN OF TREADS OR FLIGHT WITH FOUR OR |
| | MORE RISERS. R311.7.8.1 HEIGHT. |
| | HANDRAIL HEIGHT, MEASURED VERTICALLY FROM THE SLOPED |
| | PLANE ADJOINING THE TREAD NOSING, OR FINISH SURFACE OF |
| | RAMP SLOPE, SHALL BE NOT LESS THAN 34 INCHES (864 MM) |
| | AND NOT MORE THAN 38 INCHES (965 MM). |
| | |
| | SECTION 1013 GUARDS |
| | |
| | 1013.3 HEIGHT. |
| | REQUIRED GUARDS SHALL NOT BE LESS THAN 42 INCHES (1067 |
| | MM) HIGH, MEASURED VERTICALLY AS FOLLOWS: |
| | |
| | 1. FROM THE ADJACENT WALKING SURFACES; |
| | |
| | 2. ON STAIRS, FROM THE LINE CONNECTING THE LEADING |
| | EDGES OF THE TREAD NOSINGS; |
| | |
| | 1013.4 OPENING LIMITATIONS. |
| | REQUIRED GUARDS SHALL NOT HAVE OPENINGS WHICH ALLOW |
| | PASSAGE OF A SPHERE 4 INCHES (102 MM) IN DIAMETER FROM |
| | THE WALKING SURFACE TO THE REQUIRED GUARD HEIGHT. |
| | |
| | |
| | 3. ON RAMPS, FROM THE RAMP SURFACE AT THE GUARD. |
| | |
| | |
| | |