2016-07-31 07:48:231) THE SHOWER SHALL BE NOT LESS THAN 30 INCHES WIDE IN
 THE LEAST DIMENSION AND SHALL BE A MINIMUM OF 900
 SQUARE INCHES.SHOWER COMPARTMENTS NOT LESS THAN 25
 INCHES IN MINIMUM DIMENSIONS SHALL BE A MINIMUM OF 1300
 SQUARE INCHES. 2014 FBC-PLUMBING SEC.417.4.THE PLANS
 SHOW THE MASTER BATH SHOWER WITH A DIMENSION OF 24
 INCHES AT ONE END.
 2) INDICATE ON THE PLAN IF ANY OF THE OTHER PLUMBING
 FIXTURES ARE BEING RELOCATED.WPB AMEND. TO FBC SEC.
 107.2.1.
  
 PLUMBING PLAN REVIEW
 TIM LARGE
 CHIEF PLUMBING INSPECTOR