| Plan Review Notes For Permit 16070380 |
| Permit Number |
16070380 |
|
| Review Stop |
E |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2016-07-14 10:14:18 | REVIEW 2014 5TH FBC ED. NEC 2011 | | | MARIO VALDES | | | ELECTRICAL PLAN EXAMINER | | | 561-805-6713 | | | [email protected] | | | | | | - PROVIDE AN ELECTRICAL FLOOR PLAN SHOWING LOCATIONS OF | | | SMOKE DETECTORS, KITCHEN COUNTERTOP GFCI, BATHROOM | | | GFCI, LIGHTING IN ALL AREAS WITHIN THE SCOPE OF WORK. | | | FBC 107 MINIMUM PLAN REVIEW. | | | | | | - FBC R E3901.2.4 COUNTERTOP RECEPTACLES, FBC R E3901.3 | | | SMALL APPLIANCE RECEPTACLES, FBC R E3902.6 KITCHEN | | | RECEPTACLES, FBC R E3902.1 BATHROOM RECEPTACLES. | | | | | | - SMOKE DETECTORS SHALL BE INSTALLED PER RESIDENTIAL | | | CODE SECTIONS 314 & 315. ALL NEW RECEPTACLES SHALL BE | | | TAMPER RESISTANT IN ACCORDANCE WITH FBC R E4002.14 | | | |
|