| Date |
Text |
| 2016-07-12 06:19:09 | BUILDING PLAN REVIEW |
| | W. P. B. PERMIT: 16070328 |
| | ADD: 2708 BROADWAY |
| | CONT: GULFSTREAM ROOFING/ REROOF FLAT ROOF |
| | TEL: 786-357-5327 |
| | E-MAIL: [email protected] |
| | |
| | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| | ADMINISTRATION |
| | |
| | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. |
| | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND |
| | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE |
| | FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 1ST REVIEW |
| | DATE: TUES. JULY 12/2016 |
| | ACTION: DENIED |
| | |
| | 1) THE ROOFING PACKAGE SUBMITTED HAS A COVER LETTER |
| | STATING THIS PACKAGE IS IN DRAFT FORMAT. PLEASE |
| | RESUBMIT ONCE THE PACKAGE IS COMPLETE AND ALL PAPERWORK |
| | REQUIRED CAN BE OBTAINED, THEN SUBMIT TO THE BUILDING |
| | DEPARTMENT. |
| | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| | ADMINISTRATION 107.2.1.2 FOR ROOF ASSEMBLIES REQUIRED |
| | BY THE CODE, THE CONSTRUCTION DOCUMENTS SHALL |
| | ILLUSTRATE, DESCRIBE AND DELINEATE THE TYPE OF ROOFING |
| | SYSTEM, MATERIALS, FASTENING |
| | REQUIREMENTS, FLASHING REQUIREMENTS AND WIND RESISTANCE |
| | RATING THAT ARE REQUIRED TO BE INSTALLED. PRODUCT |
| | EVALUATION AND INSTALLATION SHALL INDICATE COMPLIANCE |
| | WITH THE WIND CRITERIA REQUIRED FOR THE SPECIFIC SITE |
| | OR A STATEMENT BY AN ARCHITECT OR ENGINEER FOR THE |
| | SPECIFIC SITE MUST BE SUBMITTED WITH THE CONSTRUCTION |
| | DOCUMENTS. |
| | |
| | 2) REROOF FLAT ROOF: THE PRODUCT APPROVAL SUBMITTED IS |
| | A MIAMI-DADE NOA 14-1030.02 GAF RUBEROID MODIFIED |
| | BITUMEN ROOF SYSTEM FOR WOOD DECKS. SHEETS 26 & 27 |
| | SUBMITTED MEMBRANE TYPE SBS/SBS COLD APPLIED WOOD DECK |
| | NON-INSULATED. PLEASE BE AWARE THERE ARE 7 OPTIONS |
| | WITHIN THIS SYSTEM, EACH WITH VARYING PRESSURES DUE TO |
| | THE NAILING PATTERNS. ALL OF THE OPTIONS ARE LOW IN |
| | PRESSURES AND ALL OPTIONS ALLOW GENERAL LIMITATION # 7 |
| | WHICH REQUIRES ENHANCED FASTENING CALCULATIONS (RAS |
| | 117) BY EITHER A FLORIDA ENGINEER OR ARCHITECT. NOTE |
| | EXPOSURE C. 2014 FBC-B , 1609.6.4.4.1 COMPONENTS & |
| | CLADDING. |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | |
| | |
| | |
| | CONSTRUCTION SERVICES DIVISION |
| | DEVELOPMENT SERVICES DEPARTMENT |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |
| | |
| | |