| 2016-11-08 14:05:00 | RESPOND TO COMMENTS IN WRITING AND IN SEPARATE |
| | SUBMITTAL (PROVISOS) |
| | |
| | #1 ADDRESS STRIPING ALONG PARKER. PAVEMENT WILL HAVE TO |
| | BE RESTRIPED / TURNING LANE WITH THERMO PLASTIC. |
| | |
| | #2 STOP SIGN AT THE INTERSECTION WILL HAVE TO BE |
| | DESIGNED AT THE CROSSING. ADA RAMP AT THE LOCATION |
| | SPECIFIED |
| | GUIDES PEDESTRIANS OUT TO PARKER AND PARK PLACE WHERE |
| | THERE IS NO RECEIVING ADA RAMPS OR CROSSWALK STRIPING. |
| | |
| | #3 DUMPSTER WILL REQUIRE MORE ANGLE TO PROVIDE CITY |
| | SANITATION TRUCK WITH A DIRECT FRONT LOAD ENTRY. IT'S |
| | IMPORTANT TO PROVIDE |
| | A 10' CONCRETE PAD IN FRONT OF THE DUMPSTER WHERE TRUCK |
| | WEIGHT DOES NOT HINDER ASPHALT. |
| | |
| | #4 IMPORTANT MESSAGE: AS OF DECEMBER 20, 2015 THE CITY |
| | OF WEST PALM BEACH CROSS-CONNECTION CONTROL MANUAL HAS |
| | BEEN REVISED, |
| | MAKING KNOWN THAT "ALL BACKFLOW DEVICES MUST BE LEAD |
| | FREE." FOR MORE INFORMATION REFER TO THE LINK BELOW: |
| | HTTP://WPB.ORG/DEPARTMENTS/PUBLIC-UTILITIES/FORMS-PUBLI |
| | CATIONS/BACKFLOW-CROSS-CONNECTION-CONTROL-MANUAL |
| | SUBMIT THE SPECIFICATION SHEETS FOR DOMESTIC WATER |
| | BACKFLOWS RPPA AND FIRE DCDA BACKFLOWS. |
| | |