| Plan Review Notes For Permit 16061203 |
| Permit Number |
16061203 |
|
| Review Stop |
R |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2016-08-09 14:43:33 | 1- SPECIFY SHINGLES ROOF SLOPE TO VERIFY UNDERLAYMENT | | | NUMBER OF LAYERS AS REQUIRED BY SEC. R905.2.2 | | | FBC-RESIDENTIAL. | | | | | | 2- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | | FAC 61G20-3.002(33) FOR: | | | A) FLAT ROOF ASSEMBLY SPECIFIED ON PLANS. AND CLEARLY | | | IDENTIFY APPROVED ASSEMBLY ON PRODUCT APPROVAL | | | SUBMITTED TO VERIFY DESIGN PRESSURES REQUIRED BY SEC. | | | R301.2.1 FBC-RESIDENTIAL. . IF THE SELECTED ASSEMBLY | | | DOESN'T MEET THE DESIGN PRESSURES OF ALL ROOF ZONES, | | | THEN SIGNED AND SEALED RAS 117 CALCULATIONS (IF THE | | | SELECTED ASSEMBLY ALLOWS IT) WILL BE REQUIRED. | | | | | | 3- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING | | | ALL PRODUCT APPROVALS (NOT SIGNING AND SEALING) AS | | | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS. | | | |
|