| 2016-06-30 08:38:25 | PLAN REVIEW COMMENTS FOR SOLAR DOMESTIC WATER HEATER |
| | |
| | 1ST REVIEW: FBC FIFTH EDITION (2014) |
| | ROBERT MCDOUGAL, CBO |
| | COMMERCIAL COMBINATION PLANS EXAMINER |
| | (561) 805-6714 |
| | [email protected] |
| | |
| | DENIED BY BUILDING |
| | PLEASE ADDRESS THE ITEMS NOTED BELOW: |
| | |
| | 1) THE FLORIDA LICENSED ENGINEER IS REQUIRED TO SIGN BY |
| | HAND HIS HANDWRITTEN SIGNATURE (FACSIMILES ARE NOT |
| | ACCEPTABLE) ON THE PLANS AND OTHER CONSTRUCTION |
| | DOCUMENTS. FAC 61G15-23.002 DIGITAL SIGNATURES ARE ONLY |
| | ACCEPTABLE ON ELECTRONICALLY SUBMITTED DOCUMENTS. |
| | FAC61G15-23.003 |
| | |
| | 2) PLANS ARE REQUIRED TO BE DRAWN TO A MINIMUM 1/8 INCH |
| | SCALE PER 107.2.1.4. |
| | |
| | 3) PROVIDE DOCUMENTATION FROM THE MANUFACTURED BUILDING |
| | DESIGNER OF RECORD TO SHOW THAT THE BUILDING CAN SAFELY |
| | SUPPORT ALL ADDITIONAL LOADING THAT MAY BE CREATED BY |
| | INSTALLATION OF THIS PHOTOVOLTAIC SYSTEM AND SOLAR |
| | WATER HEATER COLLECTOR ON THE ROOF. FBC-R 301.1 SUBMIT |
| | A SIGNED AND SEALED LETTER FROM THE ENGINEER CERTIFYING |
| | THAT HE HAS REVIEWED THE STRUCTURE AND FOUND IT TO BE |
| | STRUCTURALLY CAPABLE OF SAFELY SUPPORTING ALL |
| | ADDITIONAL LOADING THAT WILL BE CREATED BY INSTALLATION |
| | OF THIS PHOTOVOLTAIC SYSTEM AND SOLAR WATER HEATER |
| | COLLECTOR ON THE ROOF. FBCR M2301.2.2 |
| | |
| | 4) PROVIDE THE WIND DESIGN DATA ON THE PLANS. FBCR |
| | 301.2.1 |
| | |
| | 5) PROVIDE THE MANUFACTURER'S SPECIFICATIONS, LISTING |
| | AND INSTALLATION DETAILS FOR THE SOLAR WATER HEATER |
| | SYSTEM. FBC 107.2.1 AND FBCR-M2301.3 |
| | |
| | 6) PROVIDE SPECIFIC MOUNTING AND ANCHORING DETAILS FOR |
| | THE ROOF TOP SOLAR COLLECTOR. FBCR-M2301.2.2 AND |
| | FBCR301.1 |
| | |
| | |
| | |