2016-06-27 06:59:25BUILDING PLAN REVIEW
 W. P. B. PERMIT: 16060980
 ADD: 2087 PALM BEACH LAKES BLVD.
 CONT: ALUMA-PRO ENTERPRISES
 TEL: 786-400-0560
 E-MAIL: JTELLOCALUMA-PRO.COM
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 1ST REVIEW
 DATE: MON. JUNE 27/2016
 ACTION: DENIED
  
 1) STRUCTURAL CALCULATIONS BY P.E. ROBERT WARR ONLY THE
 FRONT PAGE OF THE CALCULATIONS ARE SIGNED AND SEALED.
 PROVIDE COMPLIANCE WITH FLORIDA ADMINISTRATIVE STATUTE
 61G15-23.002(2) FL. ADMIN. CODE. A COVER SHEET OR INDEX
 SHEET FOR ENGINEERING SPECIFICATIONS MAY BE USED AND
 THAT SHEET MUST BE SIGNED IN RESPONSIBLE CHARGE OF THE
 PRODUCTION & PREPARATION OF EACH SECTION OF THE
 ENGINEERING SPECIFICATION WITH SUFFICIENT INFORMATION
 ON THE COVER SHEET OR INDEX LISTING HOW MANY PAGES ARE
 COVERED UNDER THE COVER SHEET OR INDEX SHEET.
  
 2) AWNING-CANOPY-SIGN CALCULATIONS & PLANS INDICATES IN
 THE WIND DESIGN CRITERIA THIS JOBSITE LOCATION IS
 LOCATED IN A EXPOSURE CATEGORY C. PLEASE CORRECT SEE
 THE 2014 FBC-B SECTION: 1609.4.2 SURFACE ROUGHNESS
 CATEGORIES. SURFACE ROUGHNESS C. OPEN TERRAIN WITH
 SCATTERED OBSTRUCTIONS HAVING HEIGHTS GENERALLY LESS
 THAN 30 FEET (9144 MM). THIS CATEGORY INCLUDES FLAT
 OPEN COUNTRY, AND GRASSLANDS. THIS SURFACE ROUGHNESS
 SHALL ALSO APPLY TO ANY BUILDING LOCATED WITHIN SURFACE
 ROUGHNESS BTYPE TERRAIN WHERE THE BUILDING IS WITHIN
 100 FEET HORIZONTALLY IN ANY DIRECTION OF OPEN AREAS OF
 SURFACE ROUGHNESS C OR D-TYPE TERRAIN THAT EXTENDS MORE
 THAN 600 FEET IN THE UPWIND DIRECTION AND A WIDTH
 GREATER THAN 150 FEET.
  
 3) PLEASE PROVIDE A SITE PLAN OF WHERE THESE AWNINGS
 ARE GOING TO BE INSTALLED. 2014 FLORIDA BUILDING CODE W
 2014 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING
 CODE, CHAPTER 1, ADMINISTRATION 107.2.1 INFORMATION ON
 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS SHALL BE
 DIMENSIONED AND DRAWN UPON SUITABLE MATERIAL.
 CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY
 TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK
 PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE
 PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES,
 RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING
 OFFICIAL.
  
 4) PLEASE PROVIDE ELEVATIONS OF THE BUILDING AND AT
 WHAT HEIGHT FROM GRADE THESE AWNINGS ARE TO BE
 INSTALLED ,SHOW COMPLIANCE WITH: 2014 FBC-B SECTION
 3105.3.1.1
 FABRIC AWNINGS AND FABRIC-COVERED FRAMES LOCATED OVER
 PUBLIC PROPERTY OR IN AREAS ACCESSIBLE TO THE GENERAL
 PUBLIC SHALL BE CONSTRUCTED SO THAT NO RIGID PART OF
 SUCH FABRIC AWNINGS OR FABRIC-COVERED FRAMES SHALL BE
 LESS THAN 7 FEET 6 INCHES FROM THE GRADE DIRECTLY
 BELOW, AND NO PART OF THE CLOTH DROP SHALL BE LESS THAN
 7 FEET.
  
 5) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION
 DEVELOPMENT SERVICES DEPARTMENT
 TEL: 561-805-6715
 FAX: 561-805-6676