| Date |
Text |
| 2017-03-21 12:51:32 | PLAN |
| | REVIEW COMMENTS |
| | |
| | 2ND REVIEW: FBC FIFTH EDITION (2014) |
| | ROBERT MCDOUGAL, CBO |
| | COMMERCIAL COMBINATION PLANS EXAMINER |
| | (561) 805-6714 |
| | [email protected] |
| | |
| | DENIED BY MECHANICAL |
| | PLEASE ADDRESS THE ITEMS NOTED BELOW: |
| | |
| | 1) SPECIFY THE FASTENERS THAT WILL BE USED TO ATTACH |
| | THE ANGLE BRACKETS THAT WILL ANCHOR THE AC CONDENSER |
| | THE CONCRETE PAD ON THE PLANS. FBCR-M1401.4 |
| | |
| | 2) SHOW THE LOCATION AND SIZES OF THE RETURNS FROM THE |
| | FAMILY ROOM AND THE BEDROOM IN THE PROPOSED ADDITION. |
| | FBCR-M 1602.4 |
| | |
| | 3) THE BATH EXHAUST NOTE FOR THE PROPOSED BATHROOM |
| | STATES THAT THE EXHAUST IS EXISTING. PLEASE CORRECT. |
| | FBC 107.2.1 |
| | |
| | 4) THE ENERGY FORM R405 CONTAINS NUMEROUS ERRORS. THE |
| | CITY IS WEST PALM BEACH, THE OWNER IS SIMPSON, THE |
| | BUILDER NAME IS THE OWNER SIMPSON, THE PERMIT OFFICE IS |
| | WEST PALM BEACH, THE JURISDICTION IS 604700'. THE FORM |
| | INDICATES THAT YOU ARE USING THE ADDITION ALONE TO SHOW |
| | COMPLIANCE AND NOT THE WHOLE HOUSE METHOD. BASED ON THE |
| | PLANS THAT WERE SUBMITTED THE CEILING TYPE IS UNVENTED |
| | ATTIC, THERE IS NO KITCHEN IN THE ADDITION, THERE IS |
| | ONLY ONE BEDROOM IN THE ADDITION, THE ATTIC IS |
| | UNVENTED, THE INSULATION WILL NOT BE BLOWN, THE |
| | ORIENTATION IS WRONG ( THE NORTH SIDE OF THE ADDITION |
| | ATTACHES TO THE EXISTING STRUCTURE AND THE SOUTH WALL |
| | HAS 3 WINDOWS), THE OVERHANG IS ONE FOOT NOT TWO FEET |
| | THE DOORS OF THE ADDITION ARE FRENCH DOORS WITH GLASS |
| | AREAS THAT ARE MORE THAN ONE-THIRD OF THE DOOR AREAS |
| | AND SHOULD BE INCLUDED IN THE GLAZING CALCULATIONS. |
| | PLEASE CORRECT. FBC ENERGY CONSERVATION R101.5.1.1.2 |
| | |
| | 5) THE LOAD CALCULATIONS ALSO HAS ERRORS. THE REFERENCE |
| | CITY IS INCORRECTLY LISTED AS E. FORT LAUDERDALE RATHER |
| | THAN WEST PALM BEACH. FBC 107.2.1 |
| | |
| | 6) THE OWNER/AGENT IS REQUIRED TO SIGN AND DATE THE |
| | ENERGY FORMS. FBC ENERGY CONSERVATION R103.1.1.2 |
| | |
| | 7) IN ORDER TO REDUCE PLAN REVIEW TIME, PLEASE SUBMIT A |
| | RESPONSE LETTER INDICATING HOW EACH OF THE REVIEW |
| | COMMENTS HAS BEEN ADDRESSED. |
| | |
| | |