Plan Review Notes
Plan Review Notes For Permit 16060273
Permit Number 16060273
Review Stop B
Sequence Number 4
Notes
Date Text
2016-08-08 09:37:23RESIDENTIAL (R3) REVISION ADDRESSING BUILDING PROVISO,
 FOURTH BUILDING REVIEW CHECKLIST.
 CODE: FBC 5TH EDITION (2014).
  
 08/08/16 MET WITH DON STARR TO GO OVER RE- SUBMITTAL.
  
  
 ORIGINAL COMMENT:
 1- PROVIDE PRODUCT APPROVAL (2 COPIES) FOR:
 A) FLAT ROOF . AND, IDENTIFY APPROVED ASSEMBLY TO BE
 INSTALLED. NOTE: SIGNED & SEALED RAS 117 CALCULATIONS
 WILL BE REQUIRED IF THE ASSEMBLY DOESN'T MEET THE
 DESIGN PRESSURES OF SEC. R301.
  
 NOTE: KEEP IN MIND THAT THERE ARE TWO DIFFERENT
 APPLICATIONS. THERE IS A FLAT ROOF ASSEMBLY OVER THE
 ENTRY TOWER AND THERE IS ANOTHER FLAT ROOF FOR THE
 SECOND FLOOR DECK. THE SECOND FLOOR DECK ASSEMBLY
 REQUIRES A SYSTEM THAT IS DESIGNED TO RECEIVE TILE.
  
 RESPONSE:
 ENGINEERED RAS 117 CALCULATIONS SUBMITTED REFERENCE
 FLORIDA PRODUCT APPROVAL FL2144-R5 SYSTEM W-1. FLORIDA
 PRODUCT APPROVAL FL 2144-R5 WAS REVISED WITH REVISION
 #6. THE CURRENT FLORIDA PRODUCT APPROVAL IS FL2144-R6.
 THE CURRENT FLORIDA PRODUCT APPROVAL DOESN'T HAVE
 ASSEMBLY W-1. REVISE CALCULATIONS AS REQUIRED TO MATCH
 CURRENT PRODUCT APPROVAL.
 THERE IS ANOTHER PRODUCT APPROVAL SUBMITTED. THIS ONE
 IS A MIAMI-DADE NOA. THIS MIAMI-DADE NOA IS FOR
 INSULATED ASSEMBLIES ONLY. SELECT INSULATED ASSEMBLY TO
 BE INSTALLED AND PROVIDE RAS 117 CALCULATIONS
 ACCORDINGLY.
  
  
 ORIGINAL COMMENT:
 B) SECOND FLOOR DECK UNDERLAYMENT DESIGNED TO RECEIVED
 TILE AS SPECIFIED ON PLANS. AND, IDENTIFY APPROVED
 ASSEMBLY TO BE INSTALLED. NOTE: SIGNED & SEALED RAS 117
 CALCULATIONS WILL BE REQUIRED IF THE ASSEMBLY DOESN'T
 MEET THE DESIGN PRESSURES OF SEC. R301.
 SEAL-O-FLEX NOA 15-0406.03 SUBMITTED IS FOR INSULATED
 ASSEMBLIES. ARCHITECTURAL PLANS DON'T SPECIFY INSULATED
 ASSEMBLIES.
  
 RESPONSE:
 SELECT INSULATED ASSEMBLY TO BE INSTALLED AND PROVIDE
 RAS 117 CALCULATIONS ACCORDINGLY.
  
  
  
 ORIGINAL COMMENT:
 C) INSWING ENTRY DOOR SIZE DOOR AS SHOWN ON PLANS AT
 THE STAIR HALL. PROVIDE COMPLETE FLORIDA PRODUCT
 APPROVAL COVER PAGES AND THE CORRESPONDING DRAWINGS.
  
 RESPONSE: MIAMI-DADE NOA SUBMITTED EXPIRED IN 2012 AND
 IS NOT PART OF THE FLORIDA PRODUCT APPROVAL SUBMITTED.
 IF THERE IS NO CURRENT FLORIDA PRODUCT APPROVAL, THEN
 MANUFACTURER MAY APPLY FOR LOCAL PRODUCT APPROVAL.
 ADVICE IF LOCAL PRODUCT APPROVAL IS REQUESTED FOR
 FURTHER INFORMATION REGARDING SUBMITTAL PROCESS.
  
 2- DESIGNER OF RECORD TO APPROVE IN WRITING ALL PRODUCT
 APPROVALS.
  
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 (561)805-6712
 [email protected]
  
  