Plan Review Notes
Plan Review Notes For Permit 16060181
Permit Number 16060181
Review Stop THRESHOLD
Sequence Number 3
Notes
Date Text
2016-11-04 14:14:11THRESHOLD BUILDING/ BUILDING PLAN REVIEW
 W. P. B. PERMIT: 16060181
 ADD: 1301 MERCER AVE.
 CONT: STOR-ALL CONSTRUCTION
 TEL: 561-966-0056
 E-MAIL: [email protected]
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2ND REVIEW
 DATE: FRI. NOV. 04/ 2016
 ACTION: DENIED
  
 2) THIS BUILDING BEING A 5 STORY BUILDING IS CONSIDERED
 A THRESHOLD BUILDING. / FL S. S. 553.71(7) THRESHOLD
 BUILDING MEANING ANY BUILDING WHICH IS GREATER THAN (3)
 STORIES OR 50 FT. IN HEIGHT, OR WHICH HAS AN ASSEMBLY
 OCCUPANCY CLASSIFICATION AS DENIED IN THE FLORIDA
 BUILDING CODE WHICH EXCEEDS 5,000 SQ. FT. IN AREA AND
 AN OCCUPANT CONTENT OF GREATER THAN 500 PERSONS.
  
 2A)2ND REQUEST FOR A WRITTEN THRESHOLD INSPECTION PLAN,
 IT WAS NOT INCLUDED IN THE SUBMITTED DOCUMENTS NOR PART
 OF THE STRUCTURAL NOTES ON SHEETS SS0.0 & S0.1.
 109.3.6.1 THRESHOLD INSPECTION PLAN. THE ENFORCING
 AGENCY SHALL REQUIRE A (WRITTEN/ TYPED) SPECIAL
 INSPECTOR TO PERFORM STRUCTURAL INSPECTIONS ON A
 THRESHOLD BUILDING PURSUANT TO A STRUCTURAL INSPECTION
 PLAN PREPARED BY THE ENGINEER OF RECORD. THE STRUCTURAL
 INSPECTION PLAN MUST BE SUBMITTED TO THE ENFORCING
 AGENCY PRIOR TO THE ISSUANCE OF A BUILDING PERMIT FOR
 THE CONSTRUCTION OF A THRESHOLD BUILDING. THE PURPOSE
 OF THE STRUCTURAL INSPECTION PLAN IS TO PROVIDE
 SPECIFIC INSPECTION PROCEDURES AND SCHEDULES SO THAT
 THE BUILDING CAN BE ADEQUATELY INSPECTED FOR COMPLIANCE
 WITH THE PERMITTED DOCUMENTS.
  
 2B)SEMI-COMPLIED. THRESHOLD INSPECTION FORMS. SHEET 3OF
 6 THE SPECIAL INSPECTOR D. MARK LEBLANC P.E. HAS SIGNED
 ON AS THE JOBSITE INSPECTOR. WITHIN THE SUBMITTED
 THRESHOLD INSPECTION FORMS THERE ARE DOCUMENTS FOR
 BRETT S ROSE BN5798, DOUGLAS JOSEPH RICHARD BN6661 AND
 PEDRO LUIS BOURG BN4952. IF THESE (3) INSPECTORS ARE
 GOING TO DO JOBSITE INSPECTIONS UNDER YOUR DIRECTION,
 THEN EACH OF THESE INSPECTORS WILL NEED TO SIGN PAGE 3
 OF 6 FOR JOBSITE INSPECTORS.
 1ST ROUND COMMENTS. THRESHOLD INSPECTOR: WPB AMENDMENT
 109.3.6.2 W.P.B. CONSTRUCTION SERVICES DEPARTMENT
 REQUEST FOR THRESHOLD BUILDINGS A SPECIAL INSPECTOR AS
 REQUIRED BY FL S S 553.79(5) FLORIDA STATUTES TO THE
 MINIMUM INSPECTIONS REQUIRED BY THIS CODE. THE
 THRESHOLD INSPECTION FORMS ARE REQUIRED TO BE FILED OUT
 BY ALL PARTIES WITH INTEREST, NOTARIZED AND RETURNED TO
 THIS OFFICE, AND REVIEWED AND APPROVED BEFORE PERMIT
 ISSUANCE WILL TAKE PLACE.
 2C) COMPLIED. THRESHOLD BLDG., STATEMENT/ 633 FLORIDA
 STATUTE.
 2D) NOT REQUIRED. 110.3.7.4.3 ALL SHORING AND RESHORING
 PROCEDURES, PLANS AND DETAILS..
 2E)SEMI-COMPLIED. THE ONLY INSPECTOR THAT HAS NOT
 WORKED IN THE THRESHOLD PROGRAM IN THE CITY OF WEST
 PALM BEACH IS PEDRO LUIS BOURG. REQUIRED RESUME? HAS
 NOT BEEN SUBMITTED.
 1ST ROUND OF COMMENTS. FOR THE SPECIAL INSPECTOR PLEASE
 PROVIDE A RESUME' OF INSPECTION EXPERIENCE ON PREVIOUS
 PROJECT. THE RESUME' MUST BE ACCOMPANIED BY ALL
 CERTIFICATES AS SPECIFIED HEREIN. THE BUILDING OFFICIAL
 OR HIS DESIGNEE WILL REVIEW THE RESUME'
  
 2F) COMPLIED. CONTRACTOR WILL PRODUCE A JOB SUMMARY OR
 HISTORY FOR THIS TYPE OF CONSTRUCTION.
  
 2G) SEMI- COMPLIED. THREE SETS OF PLANS SUBMITTED, IN
 AT LEAST ONE SET OF PLANS THERE ARE MISSING PLANS,
 SHEETS : A-2.1, A-2.2, A-2.3, A-3.1, A-3.2, A-3.3 &
 A-3.4.
 2014 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING
 CODE, CHAPTER 1, ADMINISTRATION, 110.3.7 THRESHOLD
 BUILDINGS, GUIDELINES AND POLICIES FOR PROJECTS
 CONCERNING SPECIAL INSPECTORS.
  
 2H)NOTICE ONLY!!! NO ACTION IS REQUIRED. PLEASE CALL
 THE CITY OF WEST PALM BEACHS AUTOMATED TELEPHONE
 INSPECTIONS LINE (561) 805-6700) FOR ALL BUILDING
 INSPECTIONS FOR AUDITING OF JOBSITE INSPECTIONS WITHOUT
 THIS THE PERMIT EXPIRES IN 6 MONTHS, ABANDONMENT OF
 JOB, NO INSPECTION ACTIVITY.
  
 2I) NOTICE ONLY!!! NO ACTION IS REQUIRED. 109.3.6
 THRESHOLD BUILDINGS, OPERATING GUIDELINES FOR THRESHOLD
 INSPECTORS #26. ASSURE THAT THE DESIGNER HAS REQUIRED
 ON THE PLANS OR SPECIFICATIONS ONE MATERIAL, APPROVED
 FOR FIRE STOPPING PENETRATIONS, FOR WALLS AND CEILINGS.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION/ DEVELOPMENT SERVICES
 DEPARTMENT
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  


Account Summary | Usage Policy | Privacy Policy