| Plan Review Notes For Permit 16060097 |
| Permit Number |
16060097 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2016-06-15 11:04:06 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC FIFTH EDITION (2014) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) THE PLANS HAVE SEVERAL REFERENCES TO THE 2010 FBC. | | | THE FBC FIFTH EDITION (2014) WENT INTO EFFECT ON JUNE | | | 30, 2015. ALL NEW PERMITS APPLIED FOR ON OR AFTER THAT | | | DATE ARE REQUIRED TO COMPLY WITH AND REFERENCE THE FBC | | | FIFTH EDITION. | | | | | | 2) THE PLANS REFERENCE CHAPTER 4 OF THE FBC IN SEVERAL | | | PLACES. THIS IS A PRIVATE SWIMMING POOL LOCATED AT A | | | SINGLE FAMILY RESIDENCE, THEREFORE, THE FBC RESIDENTIAL | | | APPLIES. SEE CHAPTER 42 FOR POOL ELECTRICAL | | | REQUIREMENTS AND CHAPTER 45 FOR OTHER REQUIREMENTS. | | | | | | 3) SUBMIT TWO COPIES OF THE REMOVEABLE CHILD BARRIER | | | MANUFACTURER'S SPECIFICATIONS AND LISTING INFORMATION. | | | FBC 107.2.1.3 | | | | | | 4) AN APPLICATION FOR THE POOL PLUMBING SUB IS REQUIRED | | | BEFORE THE PERMIT WILL BE ISSUED. |
|