| Date |
Text |
| 2017-07-21 14:31:05 | NEYITA, REMEMBER THAT REVISION FEES WILL APPLY WITH THE |
| | PROVISO. ALSO, THE CONTRACTOR ON THE PERMIT APPLICATION |
| | IS "TBD". THE CONTRACTOR NEEDS TO APPLY IN ORDER TO |
| | PROCESS THE PERMIT. |
| | THANK YOU |
| | |
| | JULIO C. GOMEZ |
| | CITY OF WEST PALM BEACH |
| | COMMERCIAL COMBINATION PLANS EXAMINER |
| | DEVELOPMENT SERVICES DEPARTMENT |
| | (561)805-6712 |
| | |
| | FROM: NEYITA LEIVA |
| | TO: [email protected] |
| | DATE: 07/20/2017 05:17 PM |
| | SUBJECT: RE: 6205 WASHINGTON RD. PERMIT #16060011 |
| | |
| | |
| | |
| | GRACIAS JULIO PORFAVOR DAME UN PROVISO QUE CREES??? |
| | |
| | SENT FROM MY IPHONE |
| | |
| | ON JUL 20, 2017, AT 4:14 PM, [email protected] WROTE: |
| | |
| | YOUR WELCOME NEYITA, |
| | I TALKED TO EDGAR DUENAS REGARDING THESE COMMENTS AND |
| | LEFT A MESSAGE TO JORGE CABA SO WE CAN FINISH |
| | PROCESSING THIS PERMIT. |
| | |
| | |
| | |
| | |
| | JULIO C. GOMEZ |
| | CITY OF WEST PALM BEACH |
| | COMMERCIAL COMBINATION PLANS EXAMINER |
| | DEVELOPMENT SERVICES DEPARTMENT |
| | (561)805-6712 |
| | |
| | HOW ARE WE DOING? PLEASE LET US KNOW BY TAKING AN |
| | ANONYMOUS SURVEY AT: |
| | HTTP://WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSE |
| | RVICES |
| | |
| | |
| | |
| | FROM: NEYITA LEIVA |
| | TO: [email protected] |
| | CC: EDGAR DUENAS , |
| | [email protected] |
| | DATE: 07/20/2017 03:10 PM |
| | SUBJECT: RE: 6205 WASHINGTON RD. PERMIT #16060011 |
| | |
| | |
| | |
| | THANK YOU JULIO |
| | |
| | SENT FROM MY IPHONE |
| | |
| | ON JUL 20, 2017, AT 2:31 PM, [email protected] WROTE: |
| | |
| | RESIDENTIAL (R3) ADDITION/ALTERATION FIFTH BUILDING |
| | REVIEW CHECKLIST. |
| | CODE: FBC 5TH EDITION (2014). |
| | |
| | NOTE: |
| | BUILDING REVIEW MAY BE APPROVED WITH PROVISO. PROVISO |
| | MEANS THAT ITEMS REQUIRED BELOW MAY BE SUBMITTED LATER |
| | AFTER THE PERMIT IS ISSUED, BUT BEFORE INSPECTIONS TO |
| | AVOID DELAYS/CONFLICTS. REVISION FEES WILL APPLY. |
| | CONTRACTOR OR OWNER TO RESPOND IN WRITING IF PROVISO |
| | OPTION IS PREFERRED AT THIS TIME (IT MAY BE DONE BY |
| | RESPONDING TO THIS E-MAIL). |
| | |
| | |
| | 1- ENERGY CALCULATIONS SUBMITTED: |
| | NOTE: NEW ENERGY CALCULATIONS WERE SUBMITTED. NEW |
| | ENERGY CALCULATIONS WERE DONE BY ANOTHER PREPARER AND |
| | THE FORM USED IS THE PRESCRIPTIVE FORM R402-2014. THE |
| | FOLLOWING COMMENTS APPLY TO THE NEW FORM SUBMITTED: |
| | A) IF USING THE PRESCRIPTIVE METHOD TO SHOW COMPLIANCE |
| | WITH THE ENERGY CODE, THEN ALL THE PRESCRIPTIVE |
| | REQUIREMENTS OF TABLE R402A MUST BE MET. THE PROPOSED |
| | ADDITION IS CONCRETE BLOCK. TABLE R402A REQUIRES A |
| | MINIMUM OF R-4 INSULATION ON THE INTERIOR OF THE WALL |
| | AND A MINIMUM OF R3 INSULATION ON THE EXTERIOR OF THE |
| | WALL. PLANS SUBMITTED DON'T COMPLY WITH THIS |
| | REQUIREMENTS. PERSON PREPARING THE ENERGY CALCULATIONS |
| | TO PROVIDE DETAILS AND SPECIFICATIONS SHOWING HOW |
| | COMPLYING WITH THIS REQUIREMENTS. ENGINEER OF RECORD TO |
| | REVISE PLANS AS WELL. SEC. R103.2 FBC-ENERGY |
| | CONSERVATION, 5TH EDITION (2014). |
| | RESPONSE: REPEAT COMMENT. NOT ADDRESSED. REVISED FORM |
| | ONLY SHOWS INSULATION FOR THE EXTERIOR SIDE OF WALL. |
| | NEED INSULATION FOR BOTH INTERIOR AND EXTERIOR SIDE. |
| | AND NEED TO PROVIDE DETAIL SHOWING HOW INSTALLING THE |
| | INSULATION ON THE EXTERIOR SIDE OF THE MASONRY WALL. |
| | |
| | B) INFORMATION ON ITEM #9A2 NEEDS TO SPECIFY THE |
| | INSULATION FOR THE INTERIOR AND EXTERIOR SIDE OF THE |
| | MASONRY WALL. TABLE R402A. SEC. R101.5.1.1.1 FBC-ENERGY |
| | CONSERVATION. |
| | |
| | NOTE: LABEL FOR WINDOWS AND DOORS WITH GLAZING SHOWING |
| | THE U-FACTOR AND SHGC FACTOR SPECIFIED ON THE ENERGY |
| | CALCULATIONS WILL BE REQUIRED. |
| | |
| | |
| | ****PLEASE DO NOT STAPLE PRODUCT APPROVALS TO PLANS. |
| | ****PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH |
| | COMMENT TO EXPEDITE THE REVIEW PROCESS. |
| | ****PLEASE REPLACE ANY REVISED DRAWING AND REMOVE OLD |
| | DRAWING. DON'T STAPLE OLD DRAWINGS WITH NEW DRAWINGS. |
| | SUBMIT OLD PLANS FOR REFERENCE TO EXPEDITE THE REVIEW |
| | PROCESS. |
| | |
| | IF YOU HAVE ANY QUESTION, PLEASE CONTACT |
| | JULIO GOMEZ |
| | COMMERCIAL COMBINATION PLANS EXAMINER |
| | DEVELOPMENT SERVICES DEPARTMENT |
| | BUILDING DIVISION |
| | (561)805-6712 |
| | [email protected] |
| | |
| | |
| | |
| | |
| | JULIO C. GOMEZ |
| | CITY OF WEST PALM BEACH |
| | COMMERCIAL COMBINATION PLANS EXAMINER |
| | DEVELOPMENT SERVICES DEPARTMENT |
| | (561)805-6712 |
| | |
| | HOW ARE WE DOING? PLEASE LET US KNOW BY TAKING AN |
| | ANONYMOUS SURVEY AT: |
| | HTTP://WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSE |
| | RVICES |
| | |