| 2016-07-05 13:47:24 | RESIDENTIAL (R3) ADDITION/ALTERATION BUILDING REVIEW |
| | COMMENTS. |
| | CODE: FBC 5TH EDITION (2014) |
| | |
| | 1- ACCORDING TO PALM BEACH COUNTY PROPERTY APPRAISER, |
| | THE FIRST FLOOR IS UNFINISHED STORAGE. THERE ARE NO |
| | CITY RECORDS FOR THE CONSTRUCTION OF AN APARTMENT AS |
| | SHOWN ON PLANS SUBMITTED. IN ADDITION ZONING DOESN'T |
| | ALLOW ANOTHER APARTMENT. ZONING MAY ALLOW ADDITIONAL |
| | LIVABLE AREA BUT NO AN INDEPENDENT APARTMENT. AFTER THE |
| | PLANS ARE REVISED, BRING PLANS TO PALM BEACH COUNTY |
| | (2300 N. JOG RD.) FOR IMPACT FEES ASSESSMENT. BRING |
| | BACK COUNTY STAMPED PLANS AND COPY OF PAID RECEIPT IF |
| | FEES ARE DUE. COUNTY IMPACT FEE ORDINANCE OF THE |
| | UNIFIED LAND DEVELOPMENT CODE. |
| | |
| | 2- FIRST FLOOR PLAN LAYOUT AND SECOND FLOOR PLAN LAYOUT |
| | ARE EXACTLY THE SAME BUT THE NAMES OF THE ROOMS ARE |
| | DIFFERENT. THE PROPOSED USE AND OCCUPANCY OF THE FIRST |
| | FLOOR IS NOT CLEAR. FOR EXAMPLE, THE LAYOUT SHOWS A |
| | ROOM WITH A CLOSET AND A BATHROOM, BUT IT IS CALLED |
| | "ENTERTAINMENT ROOM". THIS IS GENERALLY USED AS A |
| | BEDROOM AS SHOWN ON THE SECOND FLOOR PLAN. (PLAN REVIEW |
| | WILL BE DONE BASED ON THE BEDROOM USE). THE LAYOUT ALSO |
| | SHOWS A KITCHEN AND A LIVING ROOM, BUT IT IS CALLED |
| | "EXERCISE, RECREATIONAL & ENTERTAINMENT ROOM". THIS IS |
| | GENERALLY USED AS KITCHEN AND LIVING ROOM AS SHOWN ON |
| | THE SECOND FLOOR PLAN. ALSO, THE ELECTRICAL FLOOR PLANS |
| | SHOW TWO SEPARATE METERS. CLARIFY, WHY PROVIDING TWO |
| | SEPARATE METERS IF ONLY ONE UNIT IS ALLOWED. NOTE: |
| | ELECTRICAL MAY MAY NEED TO BE REVISED. |
| | FOR YOUR INFORMATION ZONING MAY ALLOW THE CONVERSION OF |
| | THE FIRST FLOOR FROM STORAGE TO LIVABLE SPACE WITH SOME |
| | RESTRICTIONS. COORDINATE WITH ZONING FOR ALLOWED USE. |
| | CLEARLY DEFINE THE USE AND OCCUPANCY OF EACH ROOM TO |
| | PERFORM A PROPER PLAN REVIEW. REVISE PLANS AS REQUIRED |
| | TO VERIFY COMPLIANCE WITH THE PROPOSED USE AND |
| | OCCUPANCY. SEC. 102.2 CITY AMENDMENTS. |
| | |
| | 3- COORDINATE WITH ITEM #3 ABOVE AND PROVIDE COMPLIANCE |
| | WITH THE EGRESS REQUIREMENTS OF THE BEDROOM ON THE |
| | FIRST FLOOR PLAN. SPECIFY WINDOW TYPE, SIZE. SEC. R310 |
| | FBC-RESIDENTIAL, 5TH EDITION (2014). |
| | |
| | 4- SCOPE OF WORK IS NOT CLEAR. CLEARLY SPECIFY EXTENT |
| | OF WORK TO BE PERFORMED. SPECIFY WHAT'S NEW , WHAT'S |
| | EXISTING, ETC. SEC. 107.2.1 CITY CITY AMENDMENTS. |
| | |
| | 5- SECOND FLOOR PLAN IS NOT DRAWN CORRECTLY. IT IS |
| | CONFUSING. IT SHOWS THE APARTMENT ENTRY DOOR THAT IS |
| | LOCATED ON THE FIRST FLOOR PLAN. REVISE AS REQUIRED. |
| | SEC. 107.2.1 CITY AMENDMENTS. |
| | |
| | 6- PROVIDE THE NAME AND SIGNATURE IN ALL PLANS OF THE |
| | PERSON RESPONSIBLE FOR THE DESIGN AS REQUIRED BY SEC. |
| | 107.2.1 CITY AMENDMENTS. |
| | |
| | 7- THIS HOUSE IS A CONTRIBUTING HISTORIC HOUSE. IT IS |
| | EXEMPT FROM THE ENERGY CODE. ENERGY CALCULATIONS ARE |
| | NOT REQUIRED, BUT IF CONTRACTOR WANTS TO SUBMIT THEM, |
| | THEN REVISE THE FOLLOWING: |
| | A) CLARIFY WHY SUBMITTING ONE ENERGY CALCULATIONS PER |
| | FLOOR. SEC. 107.2.1 CITY AMENDMENTS. |
| | |
| | B) OWNER INFORMATION IS INCORRECT. SEC. R101.5.1.1.2 |
| | FBC-ENERGY CONSERVATION, 5TH EDITION (2014). |
| | |
| | C) THE PERMIT OFFICE IS INCORRECT. THE PERMIT OFFICE IS |
| | CITY OF WEST PALM BEACH NOT PALM BEACH. TWO DIFFERENT |
| | MUNICIPALITIES. SEC. R101.5.1.1.2 FBC-ENERGY |
| | CONSERVATION, 5TH EDITION (2014). |
| | |
| | D) SPECIFY THE JURISDICTION NUMBER. SEC. R101.5.1.1.2 |
| | FBC-ENERGY CONSERVATION, 5TH EDITION (2014). |
| | |
| | E) THIS IS NOT AN ADDITION. SEE PLANS. SEC. |
| | R101.5.1.1.2 FBC-ENERGY CONSERVATION, 5TH EDITION |
| | (2014). |
| | |
| | F) NUMBER OF BEDROOMS IS INCORRECT. SEC. R101.5.1.1.2 |
| | FBC-ENERGY CONSERVATION, 5TH EDITION (2014). NOTE: THIS |
| | APPLIES TO THE ENERGY CALCULATIONS OF THE 1ST FLOOR. |
| | COORDINATE WITH REVISED PLANS AS REQUIRED BY ITEM #2 |
| | ABOVE. |
| | |
| | G) CONDITIONED FLOOR AREA IS INCORRECT. IT DOESN'T |
| | MATCH PLANS. SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION, |
| | 5TH EDITION (2014). |
| | |
| | H) PROVIDE MANUFACTURER'S DOCUMENTATION SHOWING THE |
| | DOORS AND WINDOWS U-FACTOR AND SHGC FACTOR SPECIFIED ON |
| | ITEM #7. SEC. R405.4.3 FBC-ENERGY CONSERVATION, 5TH |
| | EDITION (2014). |
| | |
| | I ) THE FLOOR TYPE AND INSULATION R-VALUE (ITEM #8) FOR |
| | THE SECOND FLOOR ENERGY CALCULATIONS IS INCORRECT. |
| | THERE IS NOT SLAB ON GRADE FOR THE SECOND FLOOR. SEC. |
| | R101.5.1.1.2 FBC-ENERGY CONSERVATION, 5TH EDITION |
| | (2014). |
| | |
| | J) PROVIDE MANUFACTURER'S INFORMATION SHOWING HOW |
| | PROVIDING R-19 INSULATION ON THE WALLS. CHECK THICKNESS |
| | OF WALL AND THICKNESS OF PROPOSED INSULATION. SEC. |
| | R405.4.3 FBC-ENERGY CONSERVATION, 5TH EDITION (2014). |
| | |
| | K) CLARIFY HOW THE CEILING OF THE FIRST FLOOR ENERGY |
| | CALCULATIONS IS VENTED AS SPECIFIED ON ITEM #10. SEC. |
| | R405.4.3 FBC-ENERGY CONSERVATION, 5TH EDITION (2014). |
| | |
| | L) PROVIDE THE NAME OF THE PERSON PREPARING THE ENERGY |
| | CALCULATIONS AS REQUIRED BY SEC. R405.4.2 FBC-ENERGY |
| | CONSERVATION, 5TH EDITION (2014). |
| | |
| | M) OWNER/AGENT TO CERTIFY AND DATE THE ENERGY |
| | CALCULATIONS AT THE BOTTOM OF THE FORM AS REQUIRED BY |
| | SEC. R103.1.1.2 FBC-ENERGY CONSERVATION, 5TH EDITION |
| | (2014). |
| | |
| | N) PAGE 2 OF 4 OF THE ENERGY CALCULATIONS FOR THE FIRST |
| | FLOOR SPECIFY THAT THERE IS A KITCHEN. FIRST FLOOR IS |
| | NOT ALLOWED TO HAVE A KITCHEN. SEE ZONING COMMENTS. |
| | COORDINATE WITH REVISED PLANS AND REVISE CALCULATIONS |
| | AS REQUIRED. SEC. R103.2 FBC-ENERGY CONSERVATION, 5TH |
| | EDITION (2014). |
| | |
| | O) ROOFING MATERIAL SHOWN ON PAGE 2 OF 4 IS INCORRECT. |
| | ACCORDING TO CITY RECORDS THE LAST ROOFING PERMIT |
| | APPLICATION FOR THE REAR STRUCTURE WAS FOR SHINGLES NOT |
| | BARREL TILE. SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION, |
| | 5TH EDITION (2014). |
| | |
| | P) WINDOWS OVERHANG SEPARATION SHOWN ON PAGE 2 OF 4 IS |
| | INCORRECT. IT DOESN'T MATCH PLANS. SEC. R101.5.1.1.2 |
| | FBC-ENERGY CONSERVATION, 5TH EDITION (2014). |
| | |
| | **** PLEASE REMOVE ANY REVISED DRAWING AND INSERT THE |
| | NEW DRAWING. DON'T STAPLE OLD DRAWINGS. SUBMIT OLD |
| | DRAWINGS FOR REFERENCE. |
| | |
| | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT |