| 2016-08-29 13:37:59 | MAIN HOUSE: |
| | RESIDENTIAL (R3) ADDITION/ALTERATION SECOND BUILDING |
| | REVIEW CHECKLIST. |
| | CODE: FBC 5TH EDITION (2014) |
| | |
| | ORIGINAL COMMENT: |
| | 1- PROVIDE COMPLIANCE WITH THE EGRESS REQUIREMENTS OF |
| | BEDROOM #1 SHOWN ON THE FIRST FLOOR PLAN. SPECIFY |
| | WINDOW TYPE, SIZE AND SILL HEIGHT SEC. R310 |
| | FBC-RESIDENTIAL, 5TH EDITION (2014). |
| | |
| | RESPONSE: |
| | THE EMERGENCY ESCAPE SHALL OPEN DIRECTLY INTO A PUBLIC |
| | WAY OR TO A YARD OR COURT THAT OPENS TO A PUBLIC WAY. |
| | SEE SEC. R310.1 FBC-RESIDENTIAL. THE DOORS SHOWN ON |
| | FLOOR PLAN DON'T COMPLY. THEY DON'T OPEN INTO A PUBLIC |
| | WAY OR YARD OR COURT THAT OPENS TO A PUBLIC WAY. REVISE |
| | PLANS AS REQUIRED. |
| | |
| | ORIGINAL COMMENT: |
| | 2- SCOPE OF WORK IS NOT CLEAR. CLEARLY SPECIFY EXTENT |
| | OF WORK TO BE PERFORMED. WHY SUBMITTING PRODUCT |
| | APPROVAL FOR SINGLE HUNG WINDOWS. WHAT'S NEW , WHAT'S |
| | EXISTING, ETC. SEC. 107.2.1 CITY CITY AMENDMENTS. |
| | |
| | RESPONSE: |
| | (1) SCOPE BUILDING NOTE #1 INDICATES "REPAIR DAMAGED |
| | EXISTING FRAMING AND STUCCO ON EXISTING EXTERIOR WALL". |
| | NEED TO INDICATE ON PLANS DAMAGED AREAS AND PROVIDE |
| | COMPLETE DETAILS AND SPECIFICATIONS FOR THE PROPOSED |
| | REPAIR. SPECIFY ALL FRAMING MEMBERS AND CONNECTORS. |
| | SEC. R301.1 FBC-RESIDENTIAL, 5TH EDITION (2014). |
| | |
| | (2) SCOPE BUILDING NOTE #3 INDICATES "INSTALL NEW |
| | INTERIOR FRAMING TO CREATE NEW UPSTAIRS BATHROOM |
| | ATTACHED TO MASTER BEDROOM". PROVIDE COMPLETE FRAMING |
| | PLANS AND SPECIFICATIONS. SPECIFY ALL FRAMING MEMBERS |
| | AND CONNECTORS. SEC. R301.1 FBC-RESIDENTIAL, 5TH |
| | EDITION (2014). |
| | |
| | ORIGINAL COMMENTS: |
| | 3- SPECIFY CARBON MONOXIDE ALARMS FOR ALL BEDROOMS |
| | SHOWING COMPLIANCE WITH SEC. R315 FBC-RESIDENTIAL. |
| | |
| | RESPONSE: |
| | CARBON MONOXIDE ALARMS TO BE INCLUDED IN THE ORIGINAL |
| | DRAWING. CORRECTIONS BY HAND ON SUBMITTED COPIES ARE |
| | NOT ALLOWED. |
| | |
| | ORIGINAL COMMENT: |
| | 4- PROVIDE THE NAME AND SIGNATURE IN ALL PLANS OF THE |
| | PERSON RESPONSIBLE FOR THE DESIGN AS REQUIRED BY SEC. |
| | 107.2.1 CITY AMENDMENTS |
| | |
| | RESPONSE: |
| | STILL MISSING THE NAME OF THE PERSON RESPONSIBLE FOR |
| | THE DESIGN. |
| | |
| | **** PLEASE REMOVE ANY REVISED DRAWING AND INSERT THE |
| | NEW DRAWING. DON'T STAPLE OLD DRAWINGS. SUBMITT OLD |
| | DRAWINGS FOR REFERENCE. |
| | |