| Plan Review Notes For Permit 16051166 |
| Permit Number |
16051166 |
|
| Review Stop |
ENG |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2016-06-11 07:40:52 | REVIEW THE DIMENSIONS AS SHOWN. | | | 16FEET VS 18FEET (DETAIL VS SITE PLAN) 16' WITH A TWO | | | FOOT OVERHANG WOULD BE OK. | | | | | | WHEEL STOPS WOULD HAVE TO BE ANCHORED ON ASPHALT OR | | | CONCRETE SURFACE NOT IN LANDSCAPE AREA. YOUR DRAWING | | | DOES NOT SPECIFY PARKING SURFACE, CONCRETE OR ASPHALT? | | | | | | SHOW DETAIL OF PROPOSED APRON (REMOVING SIDEWALK TO | | | ACCESS PARKING? ) ANY PROPOSED DRIVEWAY APRON MUST BE | | | 6" THICK 3000 PSI CONCRETE. | | | | | | CITY STANDARD STRIPPING IS "DOUBLE STRIPE" WHITE NOT | | | SINGLE STRIPE. | | | | | | VERIFY DIMENSION FROM BACK OF SIDEWALK TO BUILDING | | | WALL. I BELIEVE IT MAY BE SMALLER THAN 19.96' AS SHOWN. | | | | | | IS YOUR PARKING OFF THE ALLEY OR 4TH STREET. | | | | | | "FIRE RATING" NOTE SHOULD BE EXCLUDED. | | | | | | PROVIDE ON PLAN "PERVIOUS AREA IN SQUARE FEET, | | | IMPERVIOUS AREA IN SQUARE FEET AND BUILDING AREA IN | | | SQUARE FEET" INCLUDE YOUR PROPOSED PARKING. | | | | | | THANK YOU! | | | | | | MANUEL JULIAN GONZALEZ | | | ENGINEERING PROJECT COORDINATOR | | | PUBLIC WORKS DEPARTMENT | | | 401 CLEMATIS STREET, 4TH FLOOR | | | WEST PALM BEACH, FL 33401 | | | (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402) | | | MAIN PHONE: (561) 822-1200 | | | DIRECT: (561) 494-1085 | | | FAX: (561) 494-1116 | | | EMAIL: [email protected] | | | WWW.WPB.ORG/ENGINEERING | | | | | | | | | | | | | | | | | | | | | | | | |
|