| 2016-05-26 18:06:09 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC FIFTH EDITION (2014) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) THE PROJECT IS LOCATED IN EXPOSURE C PER FBC-R | | | 301.2.1.4.3. PLEASE CORRECT. | | | | | | 2) THE MAXIMUM DESIGN PRESSURES LISTED IN THE PRODUCT | | | APPROVAL FOR THE TARCO SELF-ADHERING MODIFIED ROOFING | | | SYSTEM ARE NOT ADEQUATE FOR THE PERIMETER AND CORNER | | | AREAS OF THE FLAT ROOF. SUBMIT SIGNED AND SEALED RAS | | | 117 CALCULATIONS FOR ENHANCED FASTENING AS REQUIRED BY | | | GENERAL LIMITATION NUMBER 7 ON PAGE 10 OF NOA NO. | | | 12-0703.06. FBC-R301.1 |
|