| 2016-05-31 06:30:15 | 1)2) SHT. A-1 - THE GRAB BARS SHALL BE MEASURED TO THE | | | TOP OF THE GRIPPING SURFACE PER 2014 FAC SEC.609.4.. | | | 3) SHT. A 1- THE CENTERLINE OF THE WATER CLOSET SHALL | | | BE 16 INCHES (405 MM) MINIMUM TO 18 INCHES (455 MM) | | | MAXIMUM FROM THE SIDE WALL. FAC SEC.604.2. SHOW ON THE | | | PLANS. | | | 4) A SERVICE SINK IS REQD. 2014 FBC-PLUMBING, TABLE | | | 403.1. | | | 5) THE COFFEE BAR COUNTER AND THE SINK SHALL COMPLY | | | WITH THE 2014 FAC SEC. 212.1 & 606.2, 606.3, 606.4, | | | 606.5. | | | 6) THE HEIGHT OF THE WATER CLOSET FROM THE FINISH FLOOR | | | SHALL COMPLY WITH FAC SEC. 604.4. | | | 7) THE BACKFLOW PREVENTER SHALL BE PERMITTED UNDER A | | | SEPARATE PERMIT. | | | | | | PLUMBING PLAN REVIEW | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | 561-805-6692 | | | [email protected] | | | | | | |
|