2016-05-31 06:30:151)2) SHT. A-1 - THE GRAB BARS SHALL BE MEASURED TO THE
 TOP OF THE GRIPPING SURFACE PER 2014 FAC SEC.609.4..
 3) SHT. A 1- THE CENTERLINE OF THE WATER CLOSET SHALL
 BE 16 INCHES (405 MM) MINIMUM TO 18 INCHES (455 MM)
 MAXIMUM FROM THE SIDE WALL. FAC SEC.604.2. SHOW ON THE
 PLANS.
 4) A SERVICE SINK IS REQD. 2014 FBC-PLUMBING, TABLE
 403.1.
 5) THE COFFEE BAR COUNTER AND THE SINK SHALL COMPLY
 WITH THE 2014 FAC SEC. 212.1 & 606.2, 606.3, 606.4,
 606.5.
 6) THE HEIGHT OF THE WATER CLOSET FROM THE FINISH FLOOR
 SHALL COMPLY WITH FAC SEC. 604.4.
 7) THE BACKFLOW PREVENTER SHALL BE PERMITTED UNDER A
 SEPARATE PERMIT.
  
 PLUMBING PLAN REVIEW
 TIM LARGE
 CHIEF PLUMBING INSPECTOR