| Date |
Text |
| 2016-05-12 11:47:10 | |
| | 1ST REVIEW: FBC 2014 |
| | |
| | GEORGE JOHNSON |
| | PLUMBING PLANS EXAMINER |
| | CITY OF WEST PALM BEACH |
| | 561-805-6711 |
| | [email protected] |
| | |
| | PLUMBING COMMENTS: |
| | |
| | 1. SHOW CLEAR FLOOR SPACE FOR BREAKROOM SINKS AND |
| | COFFEE BAR. SHALL COMPLY WITH FBC ACC. SEC. 305.3- |
| | 303.5 |
| | |
| | 2. THE DIMENSION YOU HAVE FOR TOILET HEIGHT OF 15IN. IS |
| | TO LOW. TOILET SEATS SHALL COMPLY WITH FBC ACC. SEC. |
| | 604.4 SEATS. |
| | THE SEAT HEIGHT OF A WATER CLOSET ABOVE THE FINISH |
| | FLOOR SHALL BE 17 INCHES (430 MM) MINIMUM AND 19 INCHES |
| | (485 MM) MAXIMUM MEASURED TO THE TOP OF THE SEAT. SEATS |
| | SHALL NOT BE SPRUNG TO RETURN TO A LIFTED POSITION. |
| | |
| | 3. THE HEIGHT OF THE GRAB BARS SHALL BE MEASURED TO THE |
| | TOP OF THE GRIPPING SURFACE FROM FINISHED FLOOR AT A |
| | MIN OF 33IN. AND A MAX OF 36IN PLEASE SHOW ON PLAN THAT |
| | WAY. TO COMPLY WITH FBC ACC.SEC. 609.4 |
| | |
| | 4. THE DIMENSION FROM SIDE WALL TO CENTER OF TOILET |
| | SHOULD SHOW A MIN OF 16IN AND MAX OF 18IN TO COMPLY |
| | WITH FBC ACC SEC. 604.2 |
| | |
| | 5. THE TOILET DISPENSER SHALL COMPLY WITH FBC |
| | ACC.SEC.604.7 DISPENSERS. |
| | TOILET PAPER DISPENSERS SHALL COMPLY WITH 309.4 AND |
| | SHALL BE 7 INCHES (180 MM) MINIMUM AND 9 INCHES (230 |
| | MM) MAXIMUM IN FRONT OF THE WATER CLOSET MEASURED TO |
| | THE CENTERLINE OF THE DISPENSER. THE OUTLET OF THE |
| | DISPENSER SHALL BE 15 INCHES (380 MM) MINIMUM AND 48 |
| | INCHES (1220 MM) MAXIMUM ABOVE THE FINISH FLOOR AND |
| | SHALL NOT BE LOCATED BEHIND GRAB BARS. DISPENSERS SHALL |
| | NOT BE OF A TYPE THAT CONTROLS DELIVERY OR THAT DOES |
| | NOT ALLOW CONTINUOUS PAPER FLOW. |
| | |
| | 5. THE GRAB BAR ON SIDE WALL SHALL IS MISSING THE 12IN |
| | MAX FROM REAR WALL TO COMPLY WITH FBC ACC SEC.604.5.1 |
| | SIDE WALL. |
| | THE SIDE WALL GRAB BAR SHALL BE 42 INCHES (1065 MM) |
| | LONG MINIMUM, LOCATED 12 INCHES (305 MM) MAXIMUM FROM |
| | THE REAR WALL AND EXTENDING 54 INCHES (1370 MM) MINIMUM |
| | FROM THE REAR WALL |
| | |
| | 6. PROVIDE A BACKFLOW FOR ICE MACHINES IN REF AND |
| | COFFEE MAKERS. PER FBC ACC SEC. 608.16.1 -608.3 |
| | |
| | |
| | |