| Date |
Text |
| 2016-05-31 13:31:56 | GAS COMMENTS: |
| | |
| | 1. PROVIDE LENGTH OF EACH CUT SECTION OF PIPE ON |
| | ISOMETRIC DRAWING. PER FBC FG SEC. 402.4.1-402.4.2 |
| | |
| | 2.THE NOTE FOR YOUR 2PSI SYSTEM INDICATES TABLE |
| | 402.4(18) WHICH IS CSST ON THE ISOMETRIC DRAWING YOUR |
| | REFERENCING BS PIPE WHAT DOES BS STAND FOR PLEASE |
| | CLARIFY WHAT TYPE OF PIPE YOU USING. PER WPB AMEND. TO |
| | FBC SEC. 107.2.1 |
| | |
| | 3. SUBMIT CALCULATIONS FOR COMBUSTION AIR PER THE |
| | FBC-2014 FUEL GAS CODE SEC. 304. |
| | |
| | 4.SUBMIT MANUFACTURER?S SPECIFICATION SHEETS FOR ALL |
| | GAS EQUIPMENT TO VERIFY COMPLIANCE WITH STANDARDS NFPA |
| | 54, NFPA 58, AND FBC-2014 FUEL GAS SEC. 402.2 |
| | |
| | 5. IN THE NOTES FOR THE GAS PIPING YOU ARE REFERENCING |
| | BS PIPING AND SLEEVING PIPING UNDER THE SLAB , THE |
| | ISOMETRIC DRAWING DOES NOT SHOW ANY PIP UNDER THE SLAB |
| | PLEASE CLARIFY . PLEASE REMOVE ANY NOTES THAT DO NOT |
| | APPLY TO THIS GAS SYSTEM. PER WPB AMEND. TO FBC SEC. |
| | 107.2.1 |
| | |
| | |
| | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT |
| | CORRECTED PAGES INTO TO SUBMITTAL AND LEAVE THE |
| | PREVIOUSLY REVIEWED SHEETS. |
| | DO TO PLANS BEING INCOMPLETE OR UNCLEAR, A |
| | COMPREHENSIVE PLAN REVIEW CANNOT BE DONE AT THIS TIME, |
| | THERE MAYBE ADDITIONAL COMMENTS ON RESUBMITTAL OF |
| | PLANS. |
| | |
| | |
| | GEORGE JOHNSON |
| | PLUMBING PLANS EXAMINER |
| | CITY OF WEST PALM BEACH |
| | 561-805-6711 |
| | [email protected] |
| | |
| | |
| | |