| 2016-06-29 09:30:23 | PLAN |
| | REVIEW COMMENTS |
| | |
| | 1ST REVIEW: FBC FIFTH EDITION (2014) |
| | ROBERT MCDOUGAL, CBO |
| | COMMERCIAL COMBINATION PLANS EXAMINER |
| | (561) 805-6714 |
| | [email protected] |
| | |
| | DENIED BY BUILDING |
| | PLEASE ADDRESS THE ITEMS NOTED BELOW: |
| | |
| | 1) PROVIDE A COMPLETE DESCRIPTION OF WORK ON THE PLANS. |
| | INDICATE WHICH WINDOWS AND DOORS ARE TO BE REPLACED. |
| | FBC 107.2.1 |
| | |
| | 2) THIS APPEARS TO BE A LEVEL 3 ALTERATION. PROVIDE A |
| | FLOOR PLAN OF THE EXISTING BUILDING. FBC EXISTING |
| | BUILDING 505 AND FBC 107.2.1 |
| | |
| | 3) SHOW COMPLIANCE WITH FBC ENERGY CONSERVATION SECTION |
| | R101.4.3 BY SUBMITTING THE REQUIRED CONSTRUCTION |
| | DOCUMENTS. FBC ENERGY CONSERVATION R101.5.1 |
| | |
| | 4) PROVIDE ADDITIONAL DETAILS ON THE STEEL COLUMN CAP |
| | INCLUDING THE WELDS. FBC 107.2.1 |
| | |
| | 5) FBC 107.3.4 - PROVIDE TWO SETS OF PRODUCT APPROVALS |
| | FOR THOSE PRODUCTS WHICH ARE REGULATED BY DCA RULE 9N-3 |
| | THAT HAVE BEEN REVIEWED AND APPROVED IN WRITING BY THE |
| | DESIGNER OF RECORD. PROVIDE TWO COMPLETE PRODUCT |
| | APPROVALS WITH FL OR NOA NUMBERS INCLUDING INSTALLATION |
| | INSTRUCTIONS AND MAXIMUM DESIGN PRESSURES FOR EACH OF |
| | THE DIFFERENT ROOFING MATERIALS, WINDOW/GLASS TYPES, |
| | IMPACT PROTECTION DEVICES AND EXTERIOR DOOR TYPES. |
| | |
| | 6) ON SHEETS 3 AND 8, THE CONSTRUCTION TYPE SHOULD BE |
| | V-B AND THE OCCUPANCY IS R-3 SINGLE FAMILY DWELLING. ON |
| | SHEET 3 THE 2010 FBC EDITION OF THE CODE IS CITED AND |
| | IT SHOULD BE THE 2014 FBC. |
| | |
| | 7) IN ORDER TO REDUCE PLAN REVIEW TIME, PLEASE SUBMIT A |
| | RESPONSE LETTER INDICATING HOW EACH OF THE REVIEW |
| | COMMENTS HAS BEEN ADDRESSED. |
| | |
| | |
| | |