| Date |
Text |
| 2016-06-02 13:45:47 | BUILDING PLAN REVIEW |
| | W. P. B. PERMIT: 16041215 |
| | ADD: 2001 S. DIXIE HWY. |
| | CONT: MAC ENTERPRISES |
| | TEL: 561-236-3627 |
| | E-MAIL: [email protected] |
| | |
| | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| | ADMINISTRATION |
| | |
| | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. |
| | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND |
| | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE |
| | FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 2ND REVIEW |
| | DATE: THURS. JUNE 02/ 2016 |
| | ACTION: BUILDING PROVISO |
| | |
| | 1) THE INTERIOR STAIRWAY WITH SHORT TREADS, PLEASE |
| | REVIEW THE BUILDING OFFICIAL ROBERT BROWNS REQUIREMENTS |
| | TO CREATE A CODE COMPLIANT SET OF STAIRS. 1009.7.2 |
| | RISER HEIGHT AND TREAD DEPTH. |
| | STAIR RISER HEIGHTS SHALL BE 7 INCHES (178 MM) MAXIMUM |
| | AND 4 INCHES (102 MM) MINIMUM. THE RISER HEIGHT SHALL |
| | BE MEASURED VERTICALLY BETWEEN THE NOSINGS OF ADJACENT |
| | TREADS. RECTANGULAR TREAD DEPTHS SHALL BE 11 INCHES |
| | (279 MM) MINIMUM MEASURED HORIZONTALLY BETWEEN THE |
| | VERTICAL PLANES OF THE FOREMOST PROJECTION OF ADJACENT |
| | TREADS AND AT A RIGHT ANGLE TO THE TREAD?S NOSING. |
| | |
| | 2A) 2014 FBC-B 1609.1.2 PROTECTION OF OPENINGS, |
| | 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA DEPARTMENT |
| | OF COMMUNITY AFFAIRS RULE 9N-3 NOV. 01/ 2010 (31) |
| | SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION SYSTEMS THAT |
| | WILL REQUIRE PRODUCT APPROVALS: |
| | (31)(A) EXTERIOR DOORS. |
| | (B) WINDOWS |
| | (C) PANEL WALLS: STOREFRONTS, CURTAIN WALLS, WALL |
| | LOUVERS, EFIS SYSTEMS, |
| | (D) ROOFING PRODUCTS AND ASSEMBLIES |
| | (E) SHUTTERS |
| | (F) SKYLIGHTS |
| | (G) PRE-ENGINEERED A/C STANDS |
| | |
| | 2B) 107.3.4.1 THOSE PRODUCTS WHICH ARE REGULATED BY DCA |
| | RULE 9N-3 SHALL BE REVIEWED AND APPROVED IN WRITING BY |
| | THE DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR |
| | JURISDICTIONAL APPROVAL. |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | CONSTRUCTION SERVICES DIVISION |
| | DEVELOPMENT SERVICES DEPARTMENT |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |