| Date |
Text |
| 2016-06-03 16:01:09 | PLAN |
| | REVIEW COMMENTS |
| | |
| | 1ST REVIEW: FBC FIFTH EDITION (2014) |
| | ROBERT MCDOUGAL, CBO |
| | COMMERCIAL COMBINATION PLANS EXAMINER |
| | (561) 805-6714 |
| | [email protected] |
| | |
| | DENIED BY BUILDING |
| | PLEASE ADDRESS THE ITEMS NOTED BELOW: |
| | |
| | 1) THE PLANS SPECIFY EXPOSURE C AND THE PROJECT IS |
| | LOCATED IN EXPOSURE D PER FBC-R301.2.1.4.3 |
| | |
| | 2) PROVIDE A SECTION THROUGH THE PROPOSED OPEN PORCH |
| | FLOOR FOR CLARIFICATION. FBC 107.2.1.3 |
| | |
| | 3) THE PLANS SHOW AN EXISTING DOUBLE OUTSWING DOOR THAT |
| | OPENS ONTO AN EXISTING OPEN DECK ON THE SECOND FLOOR. |
| | PLEASE CLARIFY HOW RAISING THE DECK APPROXIMATELY 7" |
| | WILL AFFECT THE EXISTING DOOR. FBC 107.2.1 |
| | |
| | 4) FBC 107.3.4 - PROVIDE TWO SETS OF PRODUCT APPROVALS |
| | FOR THOSE PRODUCTS WHICH ARE REGULATED BY DCA RULE 9N-3 |
| | THAT HAVE BEEN REVIEWED AND APPROVED IN WRITING BY THE |
| | DESIGNER OF RECORD. PROVIDE TWO COMPLETE PRODUCT |
| | APPROVALS WITH FL OR NOA NUMBERS INCLUDING INSTALLATION |
| | INSTRUCTIONS AND MAXIMUM DESIGN PRESSURES FOR THE |
| | ROOFING MATERIAL. |
| | |
| | 5) SHOP DRAWINGS OF THE ALUMINUM RAILINGS THAT HAVE |
| | BEEN APPROVED IN WRITING BY THE DESIGNER OF RECORD ARE |
| | REQUIRED TO SUBMITTED FOR REVIEW AND APPROVAL BEFORE |
| | THEY ARE INSTALLED. FBC 107.2.1.3 |
| | |
| | 6) THE DESIGNER OF RECORD IS REQUIRED TO REVIEW THE |
| | EXISTING STRUCTURAL SUPPORT BEAMS, COLUMNS AND |
| | FOUNDATION TO VERIFY THAT THEY ARE CAPABLE OF SAFELY |
| | SUPPORTING THE PROPOSED CONSTRUCTION. SUBMIT A SIGNED |
| | AND SEALED STRUCTURAL EVALUATION REPORT. FBC 107.2.1.3 |
| | |
| | 7) IN ORDER TO REDUCE REVIEW TIME, SUBMIT A RESPONSE |
| | LETTER THAT INDICATES HOW EACH OF THE COMMENTS HAS BEEN |
| | ADDRESSED. |
| | |
| | |