| Date |
Text |
| 2016-05-24 14:03:23 | ****CORRECTIONS**** |
| | |
| | SAMANTHA HILL |
| | BUILDING PLANS EXAMINER |
| | [email protected] |
| | 561-805-6724 |
| | |
| | 1. LS1.1, IT IS NOT CLEAR WHETHER OR NOT A CHANGE OF |
| | OCCUPANCY IS APPLICABLE. REVISE PLAN TO INCLUDE THIS |
| | INFORMATION. |
| | |
| | 2. LS1.1, CODE ANALYSIS REFERS TO A LAB, BUT I WAS |
| | UNABLE TO LOCATE ON THE PLAN, FBC 107. |
| | |
| | 3. REVISE PLAN TO SHOW THE 18" CLEARANCE, PULL SIDE, |
| | FBC 5TH ED. ACCESSIBILITY FIGURE 404.2.4.1 FOR DOORS |
| | 106-1, 108-1, 119-2, DOOR TO FEMALE BATHROOM. |
| | |
| | 4. REVISE PLAN TO SHOW CORRIDOR WIDTH, REQUIRED WIDTH, |
| | TO SHOW COMPLIANCE WITH FBC 5TH ED. BUILDING 1005.7.1. |
| | |
| | 5. USE OF THE MULTI PURPOSE ROOM IS NOT ENTIRELY CLEAR. |
| | SEE FBC 5TH ED. ACCESSIBILITY 221. ALSO CLARIFY THE USE |
| | OF WHAT APPEARS TO BE WORK STATIONS. REVISE THE PLAN TO |
| | CLARIFY COMPLIANCE WITH (OR EXEMPTION TO) ACCESSIBILITY |
| | REQUIREMENTS. |
| | |
| | 6. A ROOF REPORT WAS PROVIDED. INDICATE THE ASSEMBLY |
| | PROPOSED AND, IF REQUIRED, PROVIDE ENGINEERING. IF THIS |
| | IS NOT PROVIDED WITH THE RESUBMITTAL, THIS INFORMATION |
| | WILL BE REQUIRED WITH THE ROOF PERMIT APPLICATION. |
| | |
| | 7. SHEET A6.2, HARDWARE AND FIRE RATING FOR DOORS |
| | COLUMNS ARE BLANK. NOT ALL DOORS ON THE PLAN (FOR |
| | INSTANCE, THE MULTI PURPOSE ROOM) ARE LABELED. FIRE |
| | RATED WALLS AND A SMOKE PARTITION ARE SHOWN, BUT THE |
| | DOOR SCHEDULE DOES NOT INDICATE THAT ANY DOORS WILL BE |
| | RATED. REVISE TO CLARIFY, FBC 107. |
| | |
| | 8. IF THIS INCLUDES A CHANGE OF OCCUPANCY, IMPACT FEE |
| | ASSESSMENT FROM PALM BEACH COUNTY IS REQUIRED. |
| | 561-233-5025 FOR MORE INFORMATION. |
| | |
| | 9. PLEASE SEE PLUMBING COMMENTS REGARDING ACCESSIBLE |
| | ELEMENTS. |
| | |
| | 10. COURTESY ADVISORY TO WARREN JOHNSON, PE; PLEASE SEE |
| | FS 471.0195 AND 61G15-22.001, AN ADVANCED BUILDING CODE |
| | COURSE IS REQUIRED BY JUNE 30, 2016. EVIDENCE IS TO BE |
| | PROVIDED TO FBPE FOR WWW.MYFLORIDALICENSE.COM UPDATE. |
| | |
| | FOR MORE INFORMATION, SEE PAGE 4: |
| | |
| | HTTPS://WWW.FBPE.ORG/INDEX.PHP/FILE-DOWNLOADS/SEND/56-2 |
| | 015-2016-FBPE-NEWSLETTERS/377-APRIL-2016-FBPE-NEWSLETTE |
| | R |
| | |
| | |
| | |
| | |