Plan Review Notes
Plan Review Notes For Permit 16040833
Permit Number 16040833
Review Stop B
Sequence Number 6
Notes
Date Text
2017-03-22 15:59:54****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 FLORIDA BUILDING CODE, BUILDING 5TH EDITION (2014)
 SECTION 1609:
  
 1. CALCULATIONS ARE FOR 20% SOLID SURFACE. PLANS ARE
 FOR 75% OPEN; REVISE SO THE TWO ARE CONSISTENT. (DESIGN
 CRITERIA HAS CHANGED FROM 80% OPEN TO 75% OPEN SINCE
 PREVIOUS REVIEW, COMMENTS REVISED TO REFLECT THE NEW
 DESIGN CRITERIA).
  
 2. SEE PREVIOUS LIST REGARDING WIND DIRECTION: THE
 PROPOSED GATE IS NOT MEET THE 75% OPEN CRITERIA
 (REQUIREMENT BASED
 ON THE GATE FOUNDATION ABILITY TO WITHSTAND WIND LOADS)
 UNLESS THE WIND IS PARALLEL TO THE GATE. IF THE
 WIND IS PERPENDICULAR TO THE GATE, THE WIND EFFECT WILL
 BE SIMILAR TO THE EFFECT ON A SOLID SURFACE.
  
 THIS ISSUE HAS BEEN DISCUSSED WITH THE BUILDING
 OFFICIAL. IF THE ENGINEER OF RECORD DISAGREES, PLEASE
 HAVE
 HIM CALL ROBERT BROWN, 561-805-6652 OR EMAIL RATIONALE
 FOR THIS DESIGN MEETING HIS REQUIREMENT OF 75% OPEN
 TO [email protected] (AND PLEASE CC [email protected]).
  
 3. THE FOUNDATION DETAIL (PREPARED BY EVAN KENNEDY, PE,
 NO DATE, 8.5 X 11) IS NOT SIGNED AND SEALED IN
 ACCORDANCE WITH FS471 AND FAC61G15-23.002; ALSO THIS
 APPEARS TO BE THE FOUNDATION DETAIL FOR THE GATE ARM. I
 HAVE VOIDED THIS PAGE.
  
  