| Date |
Text |
| 2016-06-02 09:07:07 | 1- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY |
| | FAC 61G20-3.002(33) FOR: |
| | A) PITCHED ROOF UNDERLAYMENT. LIMITATION #2 OF THE |
| | FLORIDA PRODUCT APPROVAL FL17322-R1 SUBMITTED SPECIFIES |
| | THAT WIND UPLIFT RESISTANCE IS NOT WITHIN THE SCOPE OF |
| | THIS EVALUATION. NEED TO PROVIDE INFORMATION SHOWING |
| | COMPLIANCE WITH THE WIND RESISTANCE BASED ON THE |
| | PROPOSED INSTALLATION. COORDINATE WITH ITEM # 16 BELOW. |
| | CLEARLY SPECIFY WHICH UNDERLAYMENT IS GOING TO BE USED. |
| | ALSO, PROVIDE ROOF TILE PRODUCT APPROVAL THAT LISTS |
| | THIS UNDERLAYMENT.. |
| | |
| | B) "FLAT ROOF BASE SHEET" NOA 13-1113.05 SUBMITTED IS |
| | FOR SLOPED ROOFS ONLY. PROVIDE PRODUCT APPROVAL FOR |
| | FLAT ROOF ASSEMBLIES. AND, CLEARLY IDENTIFY APPROVED |
| | ASSEMBLY TO BE INSTALLED. AND, PROVIDE SIGNED AND |
| | SEALED RAS 117 CALCULATIONS IF THE DESIGN PRESSURES OF |
| | THE SELECTED ASSEMBLY DON'T MEET THE DESIGN PRESSURES |
| | FOR ALL THE ROOF ZONES. |
| | |
| | C) "FLAT ROOF WATERPROOFING" NOA 12-0418.02 SUBMITTED |
| | IS FOR INSULATED WOOD DECK ASSEMBLIES. THERE ARE NO |
| | INSULATED WOOD DECK ASSEMBLIES IN THIS PROJECT. PROVIDE |
| | PRODUCT APPROVAL FOR FLAT ROOF ASSEMBLIES. COORDINATE |
| | WITH ITEM #14(E) ABOVE. ALSO, REMEMBER THAT THERE ARE |
| | SOME CONCRETE DECKS SHOWN ON PLANS. PROVIDE PRODUCT |
| | APPROVAL FOR SUCH ASSEMBLIES. |
| | |
| | D) IPE TILE ROOF DECK PEDESTAL SYSTEM. NEED TO SHOW |
| | COMPLIANCE WITH THE CALCULATED DESIGN PRESSURES. |
| | |
| | E) ROOF TILE ADHESIVE, IF SPECIFIED BY THE DESIGNER OF |
| | RECORD. |
| | |
| | 2- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING |
| | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS |
| | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS TO VERIFY |
| | COMPLIANCE WITH THE COMPONENTS AND CLADDING DESIGN |
| | PRESSURES. |
| | |
| | 3- DESIGNER OF RECORD TO SPECIFY ROOF TILE FASTENING AS |
| | REQUIRED BY SEC. 107.2.1.2 CITY AMENDMENTS. IF |
| | SPECIFYING SCREWS, THEN SPECIFY SIZE AND NUMBER OF |
| | SCREWS. IF SPECIFYING ADHESIVE, THEN ADHESIVE PRODUCT |
| | APPROVAL IS REQUIRED. |
| | |
| | |
| | APPROVED PRODUCT APPROVALS: |
| | |
| | 1- ALTUSA "S" CLAY ROOF TILE NOA 14-0605.03 |