| Date |
Text |
| 2017-01-30 10:31:50 | BUILDING PLAN REVIEW |
| | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1 |
| | ADMINISTRATION |
| | |
| | CHRISTOPHER S. THROOP, C.B.O. |
| | BUILDING PLANS EXAMINER, PX3169 |
| | CONSTRUCTION SERVICES DIVISION |
| | TEL: 561-805-6726 |
| | FAX: 561-805-6676 |
| | |
| | 2ND REVIEW |
| | RESULTS: DENIED |
| | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT |
| | |
| | 1. VALUE INCREASED BY $4,800 (PYLON SIGNAGE INSTALL). |
| | 2. DESCREPENCY OF DEMENSIONS (WIDTH) FOR AUGER DRILLED |
| | PIERS BETWEEN ROBERT W. WALL, P.E. (3'-0") AND JOHN F. |
| | DOUGHERTY, P.E. (1'-6"). PLEASE CLARIFY. |
| | 3. DESCREPENCY OF DESIGN WIND LOADS FOR PYLON SIGN |
| | BETWEEN ROBERT W. WALL, P.E. (ASCE 7-10 - EXPOSURE C - |
| | 175 MPH) AND JOHN F. DOUGHERTY, P.E. (FL BLDG. CODE, |
| | 5TH ED 2014 - VULT - 170 MPH, EXPOSURE B). PLEASE |
| | CLARIFY. |
| | 4. PROVIDE CONNECTION DETAIL FOR PYLON SIGN DISPLAY |
| | CABINET TO ALUMINUM ANGLE FRAMING. |
| | |
| | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. |
| | CONSTRUCTION DOCUMENTS SHALL BE |
| | DIMENSIONED AND DRAWN UPON SUITABLE MATERIAL. |
| | CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY |
| | TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK |
| | PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE |
| | PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES, |
| | RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING |
| | OFFICIAL. SUCH DRAWINGS AND SPECIFICATIONS SHALL |
| | CONTAIN INFORMATION, IN THE FORM OF NOTES OR OTHERWISE, |
| | AS TO THE QUALITY OF MATERIALS, WHERE QUALITY IS |
| | ESSENTIAL TO CONFORMITY WITH THE TECHNICAL CODES. SUCH |
| | INFORMATION SHALL BE SPECIFIC, AND THE TECHNICAL CODES |
| | SHALL NOT BE CITED AS A WHOLE OR IN PART, NOR SHALL THE |
| | TERM "LEGAL" OR ITS EQUIVALENT BE USED AS A SUBSTITUTE |
| | FOR SPECIFIC INFORMATION. |
| | |
| | |
| | |