| 2016-04-13 16:58:19 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE |
| | MARSHAL, WITH THE FOLLOWING COMMENTS: |
| | |
| | 1) SHEET A 1 - AN OCCUPANCY TYPE IS NOT INDICATED. |
| | PLEASE PROVIDE THE PROPOSED OCCUPANY TYPE. |
| | |
| | 2) SHEET A 1 - AN OCCUPANCY CALCULATION AND LOAD IS NOT |
| | INDICATED. PLEASE PROVIDE AN OCCUPANCY CALCULATION AND |
| | LOAD. |
| | |
| | 3) SHEET A 1 - THE COMMON PATH OF TRAVEL FROM THE |
| | MEZZANINE IS NOT INDICATED AND SHALL COMPLY WITH THE |
| | APPROPRIATE OCCUPANCY CHAPTER OF NFPA 101. |
| | |
| | 4) SHEET A 1 - EXITING THROUGH THE WAREHOUSE AREA IS |
| | INDICATED. EXITING THROUGH THE WAREHOUSE IS NOT |
| | PERMITED PER NFPA 101, CHAPTER 7, MEANS OF EGRESS. |
| | |
| | 7.5 ARRANGEMENT OF MEANS OF EGRESS. |
| | 7.5.2 IMPEDIMENTS TO EGRESS. SEE ALSO 7.1.9 AND |
| | 7.2.1.5. |
| | 7.5.2.1* ACCESS TO AN EXIT SHALL NOT BE THROUGH |
| | KITCHENS, STOREROOMS OTHER THAN AS PROVIDED IN CHAPTERS |
| | 36 AND 37, RESTROOMS, WORKROOMS, CLOSETS, BEDROOMS OR |
| | SIMILAR SPACES, OR OTHER ROOMS OR SPACES SUBJECT TO |
| | LOCKING, UNLESS PASSAGE THROUGH SUCH ROOMS OR SPACES IS |
| | PERMITTED FOR THE OCCUPANCY BY CHAPTER 18, 19, 22, OR |
| | 23. |
| | |
| | 5) SHEET A 1 - A RAMP IS INDICATED IS INDICATED IN THE |
| | MEANS OF EGRESS. |
| | |
| | NO RAMP DETAIL IS INDICATED. |
| | |
| | NO HANDRAILS OR HANDRAIL DETAILS IS INDICATED. |
| | |
| | PER NFPA 101, CHAPTER 7, MEANS OF EGRESS. |
| | |
| | 7.2.5 RAMPS. |
| | 7.2.5.1 GENERAL. EVERY RAMP USED AS A COMPONENT IN A |
| | MEANS OF EGRESS SHALL CONFORM TO THE GENERAL |
| | REQUIREMENTS OF SECTION 7.1 AND TO THE SPECIAL |
| | REQUIREMENTS OF 7.2.5. |
| | |
| | 7.2.5.4 GUARDS AND HANDRAILS. |
| | 7.2.5.4.1 GUARDS COMPLYING WITH 7.2.2.4 SHALL BE |
| | PROVIDED FOR RAMPS, UNLESS OTHERWISE PROVIDED IN |
| | 7.2.5.4.4. |
| | 7.2.5.4.2 HANDRAILS COMPLYING WITH 7.2.2.4 SHALL BE |
| | PROVIDED ALONG BOTH SIDES OF A RAMP RUN WITH A RISE |
| | GREATER THAN 6 IN. (150 MM), UNLESS OTHERWISE PROVIDED |
| | IN 7.2.5.4.4. |
| | |
| | PLEASE PROVIDE DETAILS SHOWING COMPLIANCE. |
| | |
| | PETER LEDUC |
| | FIRE MARSHAL |
| | 561-804-4709 |
| | [email protected] |
| | |