| Date |
Text |
| 2016-06-17 16:26:59 | 2NDT REVIEW |
| | |
| | |
| | |
| | GEORGE JOHNSON |
| | PLUMBING PLANS EXAMINER LL |
| | CITY OF WEST PALM BEACH |
| | DEVELOPMENT SERVICES |
| | BUILDING DIVISION |
| | 561-805-6711 |
| | [email protected] |
| | |
| | |
| | PLUMBING COMMENTS: |
| | |
| | 1. SHT. A3 FIRST FLOOR REPLACEMENT PIPE TNE NOTE |
| | DOWNSTREAM OF CLEAN OUT CONNECT EXISTING 2IN PVC AND |
| | ABOVE IT SAYS CONNECT 4IN PVC IT IS UNCLEAR WHAT YOU |
| | DOING THERE IF THERE IS A BRANCH LINE THERE SHOW IT ON |
| | RISER AND PUT NOTE ON IT. PER WPB AMEND.TO FBC SEC. |
| | 107.2.1 |
| | |
| | 2. FIRST FLOOR RISER BATH #5 THE VENT NEEDS TO CONNECT |
| | TO LAVATORY NOT THE WATER CLOSET. COMPLY WITH FBC RES. |
| | P3101.1 |
| | |
| | 3. FIRST FLOOR RISER BATH #3 THE VENT NEEDS TO CONNECT |
| | TO LAVATORY NOT THE WATER CLOSET. COMPLY WITH FBC RES. |
| | P3101.1 |
| | |
| | 4. SHOW HEIGHT OF HANDICAP LAV. TO COMPLY WITH FBC ACC. |
| | 606.3 HEIGHT. |
| | LAVATORIES AND SINKS SHALL BE INSTALLED WITH THE FRONT |
| | OF THE HIGHER OF THE RIM OR COUNTER SURFACE 34 INCHES |
| | (865 MM) MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. |
| | |
| | 5. SHOW HEIGHT OF TOILET. TO COMPLY WITH FBC ACC.604.4 |
| | SEATS. |
| | THE SEAT HEIGHT OF A WATER CLOSET ABOVE THE FINISH |
| | FLOOR SHALL BE 17 INCHES (430 MM) MINIMUM AND 19 INCHES |
| | (485 MM) MAXIMUM MEASURED TO THE TOP OF THE SEAT. SEATS |
| | SHALL NOT BE SPRUNG TO RETURN TO A LIFTED POSITION. |
| | |
| | 6. TOILET PAPER DISPENSER SHALL COMPLY WITH FBC ACC |
| | 604.7 DISPENSERS. |
| | TOILET PAPER DISPENSERS SHALL COMPLY WITH 309.4 AND |
| | SHALL BE 7 INCHES (180 MM) MINIMUM AND 9 INCHES (230 |
| | MM) MAXIMUM IN FRONT OF THE WATER CLOSET MEASURED TO |
| | THE CENTERLINE OF THE DISPENSER. THE OUTLET OF THE |
| | DISPENSER SHALL BE 15 INCHES (380 MM) MINIMUM AND 48 |
| | INCHES (1220 MM) MAXIMUM ABOVE THE FINISH FLOOR AND |
| | SHALL NOT BE LOCATED BEHIND GRAB BARS. DISPENSERS SHALL |
| | NOT BE OF A TYPE THAT CONTROLS DELIVERY OR THAT DOES |
| | NOT ALLOW CONTINUOUS PAPER FLOW. |
| | |
| | 7. MIRROR SHALL COMPLY WITH FBC ACC. 603.3 MIRRORS. |
| | MIRRORS LOCATED ABOVE LAVATORIES OR COUNTERTOPS SHALL |
| | BE INSTALLED WITH THE BOTTOM EDGE OF THE REFLECTING |
| | SURFACE 40 INCHES (1015 MM) MAXIMUM ABOVE THE FINISH |
| | FLOOR OR GROUND. MIRRORS NOT LOCATED ABOVE LAVATORIES |
| | OR COUNTERTOPS SHALL BE INSTALLED WITH THE BOTTOM EDGE |
| | OF THE REFLECTING SURFACE 35 INCHES (890 MM) MAXIMUM |
| | ABOVE THE FINISH FLOOR OR GROUND. |
| | |
| | 8. REAR GRAB BAR SHALL COMPLY WITH FBC ACC 604.5.2 REAR |
| | WALL. |
| | THE REAR WALL GRAB BAR SHALL BE 36 INCHES (915 MM) LONG |
| | MINIMUM AND EXTEND FROM THE CENTERLINE OF THE WATER |
| | CLOSET 12 INCHES (305 MM) MINIMUM ON ONE SIDE AND 24 |
| | INCHES (610 MM) MINIMUM ON THE OTHER SIDE. |
| | |
| | 9. PROVIDE DIMENSIONS OF ACCESSIBLE SHOWERS AND SHOWER |
| | VALVES. PER WPB AMEND.TO FBC SEC. 107.2.1 |
| | |
| | 10. SHOW NEW SHOWER ON SECOND FLOW RISER DIAGRAM. PER |
| | WPB AMEND.TO FBC SEC. 107.2.1 |
| | |