| 2016-04-18 06:36:51 | BUILDING PLAN REVIEW |
| | W. P. B. PERMIT: 16040383 |
| | ADD: 777 S. FLAGLER DR. FLOORS 4TH & 5TH FLOORS. |
| | CONT: TBD |
| | TEL: 561-251-3865 |
| | E-MAIL: [email protected] |
| | |
| | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| | ADMINISTRATION |
| | |
| | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. |
| | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND |
| | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE |
| | FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 1ST REVIEW |
| | DATE: MON. APRIL 18/ 2016 |
| | ACTION: DENIED |
| | |
| | 1) THE LOCATION OF THE PROJECT, THERE SEEMS TO BE A |
| | DISCREPANCY AS TO WHERE THE LOCATION OF THE PROJECT. |
| | THE PERMIT APPLICATION UNDER THE DESCRIPTION OF WORK |
| | LIST 777 S. FLAGLER DR. 3RD & 4TH FLOORS WHERE AS THE |
| | PLAN TITLE BLOCK INDICATES THE PROJECT LOCATED AT 777 |
| | S. FLAGLER THE 4TH & 5TH FLOORS????? |
| | |
| | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| | ADMINISTRATION ADDITIONAL INFORMATION IS REQUIRED, |
| | DISCREPANCY. |
| | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| | ADMINISTRATION 107.2.1 INFORMATION ON CONSTRUCTION |
| | DOCUMENTS.. CONSTRUCTION DOCUMENTS SHALL BE OF |
| | SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND |
| | EXTENT OF THE WORK PROPOSED. |
| | |
| | 2) SHEET A4.01 INDICATES NEW CARPET (CP-1) IN THE EXIT |
| | ACCESS CORRIDOR AND NEW CARPET (CP-2) ON THE CONVENIECE |
| | STAIRS BETWEEN FLOORS. PLEASE PROVIDE COMPLIANCE WITH |
| | 2014 FBC-B SECTIONS: |
| | |
| | 804.4.2 MINIMUM CRITICAL RADIANT FLUX. |
| | IN ALL OCCUPANCIES, INTERIOR FLOOR FINISH AND FLOOR |
| | COVERING MATERIALS IN ENCLOSURES FOR STAIRWAYS AND |
| | RAMPS, EXIT PASSAGEWAYS, CORRIDORS AND ROOMS OR SPACES |
| | NOT SEPARATED FROM CORRIDORS BY PARTITIONS EXTENDING |
| | FROM THE FLOOR TO THE UNDERSIDE OF THE CEILING SHALL |
| | WITHSTAND A MINIMUM CRITICAL RADIANT FLUX. THE MINIMUM |
| | CRITICAL RADIANT FLUX SHALL NOT BE LESS THAN CLASS I IN |
| | GROUPS I-1, I-2 AND I-3 AND NOT LESS THAN CLASS II IN |
| | GROUPS A, B, E, H, I- 4, M, R-1, R-2 AND S. |
| | |
| | EXCEPTION: WHERE A BUILDING IS EQUIPPED THROUGHOUT WITH |
| | AN AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE WITH |
| | SECTION 903.3.1.1 OR 903.3.1.2, CLASS II MATERIALS ARE |
| | PERMITTED IN ANY AREA WHERE CLASS I MATERIALS ARE |
| | REQUIRED, AND MATERIALS COMPLYING WITH DOC FF-1 ?PILL |
| | TEST? (CPSC 16 CFR PART 1630) OR WITH ASTM D 2859 ARE |
| | PERMITTED IN ANY AREA WHERE CLASS II MATERIALS ARE |
| | REQUIRED. |
| | |
| | 3) SHEET A5.01 THE FURNITURE PLAN SHOWS A COURTROOM AND |
| | CONFERENCE ROOMS, PLEASE SHOW COMPLIANCE WITH 2014 |
| | FBC-ACCESSIBILTY CODE 902.3 HEIGHT. THE TOPS OF WORK |
| | SURFACES SHALL BE 28 INCHES (710 MM) MINIMUM AND 34 |
| | INCHES (865 MM) MAXIMUM ABOVE THE FINISH FLOOR OR |
| | GROUND. |
| | |
| | 4) THE CONTRACTOR TO PROVIDE A COPY OF THE CONTRACT |
| | BEFORE PERMIT ISSUANCE. THE CONTRACTOR IS TO ALSO LIST |
| | THE VALUE OF THE SUB-CONTRACTORS WORK, EVEN IF THEY |
| | COME IN UNDER A SEPERATE PERMIT, SUB-PERMITS ARE A |
| | $80.00 ADMINISTRATIVE FEE IF NOT SUBMITTED THE SAME |
| | TIME AS THE PRIME PERMIT. THE VALUE OF WORK APPEARS TO |
| | BE LOW. |
| | 108.3* BUILDING PERMIT VALUATION. |
| | IF, IN THE OPINION OF THE BUILDING OFFICIAL, THE |
| | CLAIMED VALUATION OF BUILDING, ALTERATION, STRUCTURE, |
| | ELECTRICAL, GAS, MECHANICAL, OR PLUMBING SYSTEMS |
| | APPEARS TO BE UNDER ESTIMATED ON THE APPLICATION, THE |
| | PERMIT SHALL BE DENIED. FOR PERMITTING PURPOSES, |
| | VALUATION OF BUILDINGS AND SYSTEMS SHALL BE TOTAL |
| | REPLACEMENT PURPOSES, VALUATION OF BUILDINGS AND |
| | SYSTEMS SHALL BE THE TOTAL REPLACEMENT VALUE TO INCLUDE |
| | STRUCTURAL, ELECTRICAL, PLUMBING, MECHANICAL, INTERIOR |
| | FINISHES, NORMAL SITE WORK (EXCAVATION AND BACKFILL FOR |
| | BUILDINGS), ARCHITECTURAL AND DESIGN FEES, MARKETING |
| | COST, OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE. |
| | VALUATION REFERENCES MAY INCLUDE THE LATEST PUBLISHED |
| | DATA OF NATIONAL CONSTRUCTION COST ANALYSIS SERVICES |
| | (MARSHALL-SWIFT, MEANS, ETC.) WITH REGIONAL ADJUSTMENTS |
| | FOR LOCATION AS PUBLISHED BY THE INTERNATIONAL CODE |
| | CONGRESS. |
| | |
| | 5) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION |
| | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS |
| | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL |
| | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE |
| | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION |
| | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO |
| | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| | COOPERATION. |
| | |