| Date |
Text |
| 2016-05-09 12:16:48 | 1ST REVIEW: FBC 2014 |
| | |
| | GEORGE JOHNSON |
| | PLUMBING PLANS EXAMINER |
| | CITY OF WEST PALM BEACH |
| | 561-805-6711 |
| | [email protected] |
| | |
| | PLUMBING COMMENTS: |
| | |
| | 1. TENNIS COURTS SHALL COMPLY WITH PLUMBING FIXTURE |
| | REQUIREMENTS OF TABLE FBC PL TABLE 403.1(A-4) AND |
| | 403.3.3 LOCATION OF TOILET FACILITIES IN OCCUPANCIES |
| | OTHER THAN MALLS. |
| | IN OCCUPANCIES OTHER THAN COVERED AND OPEN MALL |
| | BUILDINGS, THE REQUIRED PUBLIC AND EMPLOYEE TOILET |
| | FACILITIES SHALL BE LOCATED NOT MORE THAN ONE STORY |
| | ABOVE OR BELOW THE SPACE REQUIRED TO BE PROVIDED WITH |
| | TOILET FACILITIES, AND THE PATH OF TRAVEL TO SUCH |
| | FACILITIES SHALL NOT EXCEED A DISTANCE OF 500 FEET (152 |
| | M). |
| | PROVIDE SIT PLAN TO SHOW COMPLIANCE. |
| | |
| | 2.PROVIDE A RISER DIAGRAM FOR SANITARY AND WATER AND |
| | SHOW LOCATION ON SITE PLAN. PER WPB AMEND TO FBC SEC |
| | 107.3 107.3.5.1.3(13) |
| | |
| | 3. THE DRINKING FOUNTAIN SHALL COMPLY WITH FBC ACC. SEC |
| | 602 AND 211. OR IF YOU SHOW A COMPLIANT DRINKING |
| | FOUNTAIN WITHIN 500 FT OF TENNIS COURTS THIS FOUNTAIN |
| | DOES NOT HAVE TO COMPLY. |
| | |
| | |
| | DO TO PLANS BEING INCOMPLETE OR UNCLEAR, A |
| | COMPREHENSIVE PLAN REVIEW CANNOT BE DONE AT THIS TIME, |
| | THERE MAYBE ADDITIONAL COMMENTS ON RESUBMITTAL OF |
| | PLANS. |
| | |
| | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT |
| | CORRECTED PAGES INTO TO SUBMITTAL AND LEAVE THE |
| | PREVIOUSLY REVIEWED SHEETS. |
| | |
| | |
| | |
| 2016-05-05 10:27:57 | NOTE TO PLUMBING REVIEWER. IT IS MY UNDERSTANDING THAT |
| | THE PLUMBING CONNECTION WILL BE BY SEPARATE PERMIT |
| | APPLICATION. BIG D INDICATES THEY ARE SUPPLYING AND |
| | STRUCTURALLY CONNECTION THE FOUNTAIN, BUT NOT |
| | CONTRACTING WITH A PLUMBER TO CONNECT IT. NONETHELESS, |
| | AS A THE FOUNTAIN IS SHOWN. IF IT IS NOT COMPLIANT WITH |
| | ACCESSIBILITY CRITERIA, PERHAPS PLUMBING MAY BE MARKED |
| | NOT APPLICABLE AND THE COMMENT CAN BE ADDED TO THE |
| | BUILDING PLAN REVIEW COMMENTS. |