2016-04-05 11:49:01PLAN DENIED
 1) SHOW ACCESS TO AIR HANDLER UNITS IN ATTIC.
 REFER TO SECTION 403.2.4 FLORIDA RESIDENTIAL
 ENERGY CODE 2014
 2) SHOW SERVICE ACCESS TO AIR HANDLER 1 AND 2.
 REFER TO SECTION M1305.1 APPLIANCE ACCESS.
 2014 RESIDENTIAL CODE
 3) PROVIDE BALANCED RETURN AIR FOR BEDROOM
 #3 PER SECTION M1602.4 2014
 4) IF BEDROOM #2 IS A MASTER RETURN AIR IS TOO
 SMALL PER SECTION M1602.4
 5) CABLE OVER CONDENSER FOR TIEDOWN IS NOT ACCEPTED
 DO TO SERVICE ACCESS
 6) SHOW LOCATION OF CONDENSER ON THE PLAN. PER SECTION
 107 FBC 2014
 7) REFER TO SECTION R403.2.4 AIR HANDLER UNITS
 FLORIDA ENERGY CODE 2014
  