2016-04-04 18:05:52TRUSS PACKAGE REVIEW COMMENTS.
 FBC-5TH EDITION (2014).
  
 1- THE TRUSS DRAWINGS NEED TO BE REVIEWED AND APPROVED
 BY THE ENGINEER OF RECORD AS REQUIRED BY F.A.C. SEC.
 61G15-31.003. THE ENGINEER OF RECORD IS FARID ABUGATTAS
 NOT AFFINITY ARCHITECTS. PACKAGE WAS REVIEWED BY THE
 ARCHITECT NOT THE ENGINEER. REVISE AS REQUIRED.
  
 2- ALL DRAWINGS AND DOCUMENTS NEED THE ENGINEER'S
 ORIGINAL SEAL AND SIGNATURE AS REQUIRED BY CHAPTER 471
 FLORIDA STATUTE. RUBBER STAMP IS NOT ALLOWED.
  
 3- THE TRUSS INDEX SHEET DOESN'T COMPLY WITH FAC SEC.
 61G15-31.003. MISSING THE ENGINEER OF RECORD
 INFORMATION.
  
 4- THE INDIVIDUAL TRUSSES ARE DESIGNED BASED ON
 EXPOSURE "C". THIS BUILDING IS LOCATED IN EXPOSURE "D".
 REVISE ALL TRUSS DRAWINGS AS REQUIRED. SEC. R301 OF
 FBC-RESIDENTIAL, 5TH EDITION (2014).
  
 5- GENERAL STANDARD ENGINEERING PAGES SUBMITTED:
 A) NEED ORIGINAL SEAL AND SIGNATURE ON EACH DRAWING AS
 REQUIRED BY CHAPTER 471 FLORIDA STATUTE.
  
 B) UPDATE ALL DRAWINGS TO THE CURRENT BUILDING CODE.
 CHAPTER 553 FLORIDA STATUTE.
  
 C) UPDATE ALL DRAWINGS TO THE CORRECT BUILDING EXPOSURE
 AND THAT APPLIES TO THIS JOB. SEC. R301 OF
 FBC-RESIDENTIAL, 5TH EDITION (2014).
  
 D) SOME DRAWINGS ARE REFERENCING OLD ASCE EDITIONS AND
 THE MILES PER OUR DON'T CORRESPOND TO THE ACTUAL
 BUILDING. UPDATE AS REQUIRED. SEC. R301 OF
 FBC-RESIDENTIAL, 5TH EDITION (2014).
 NOTE: PROVIDE ONLY THE DETAILS THAT APPLY TO THIS JOB
 TO AVOID CONFLICTS/DELAYS.
  